Setting Up the Campus-RS System
S
ETTING THE
If you have mapped one or more timeslots (channels) to a data port, you must
configure the data port to support the interface type required by your
equipment. Data port type options are: Disabled, V.35, RS-449, RS-530,
RS-530A, X.21, or RS-232.
Before configuring the port type, make sure that the adapter
cables are attached to the appropriate port (Data Port 1 or
Data Port 2) and that the cables are properly attached to the
host equipment. Verify the physical port type (V.35, RS-449,
etc.) of the host equipment. Equipment damage could occur
if the ports are incorrectly configured.
To configure the data port to support the required interface type:
1
Press Escape until
2
Press Next until
3
Press Enter. The DS-0s configuration displays.
4
Press Next until one of the following displays:
PORT 1 CONFIG & STATUS
PORT 2 CONFIG & STATUS
5
Press Enter. One of the following current port configurations displays:
Disabled
V.35
RS-449
RS-530
RS-530A
X.21
RS-232
6
Press Next until the setting displays the physical type of interface on the
host equipment. To configure the port to the displayed interface, press
Enter.
7
To confirm the new setting, press Enter again. The LCD displays
CONFIG
3-6
P
T
ORT
CAMPUS RS I/F: FLEX
DATA PORT CONFIG & STATUS
and shows the new port configuration.
C
YPE
ONFIGURATION
Campus-Flex RS Interface Card User Manual
displays.