Chapter 7 Firmware Upgrade Procedure
Notice:
1.)Check FW version, it should be upgraded to latest version if it is old.
2.)Every time after Firmware upgrade, need to do DDC Keyin Procedure.
3.)
Electronically the VG700b is compatible with VG700. Please follow the
procedures shown in chapter 7 and 8 to upgrade the firmware and EDID
data.
7-1
Equipment Needed
VG700b monitor
Fixture for Firmware Upgrade
VGA Cable (P/N: 42.59901.004)* 2pcs
PC (Personal Computer)
Firmware Upgrade Program
Power Adapter (P/N: 47.58301.001)
Printer Cable
VG700B
Print Port:
to Printer cable
Printer Cable
ViewSonic Corporation
CON 2: VGA Out
CON 1: VGA In
VGA Cable (P/N : 42.59901.004)
PC
Power Adapter (P/N: 47.58301.001)
Confidential – Do Not Copy
CON3:
Print
Port
7-1
VG700b