2-a. Change your working directory to
DataMart server.
2-b. Invoke the DataMart GUI by entering the following command and pressing
pvm
2-c. Click the
Configuration
2-d. Click the
Collection
2-e. Click
Refresh
The predefined data collection requests are loaded into the Request Editor from the database.
2-f. Click the
Inactive
2-g. In the
Sub-Element Groups
groups:
Root->Sub-Element Collect->Adva Optical Metro Ethernet
2-h. Click the
Active
requests from
2-i. Click
.
Save
3.
Merge the technology pack's sub-element inventory text files.
Sub-element inventory control rules for the Adva Optical Metro Ethernet Technology Pack are contained in
the file
adva_ethernet_inventory_subelements.txt
on the DataMart server:
$PVMHOME/APFiles/adva_ethernet/datamart/conf
You must merge the contents of this file with the file
$PVMHOME/conf
To merge the sub-element inventory control rules for the Adva Optical Metro Ethernet Technology Pack,
follow these steps:
3-a. Change your working directory to
cd $PVMHOME/conf
3-b. Copy
adva_ethernet_inventory_subelements.txt
entering the following command:
cp $PVMHOME/APFiles/adva_ethernet/datamart/conf/adva_ethernet_inventory_subelements.txt .
3-c. Make a backup copy of the inventory_subelements.txt file by entering the following
command:
cp inventory_subelements.txt inventory_subelements.txt.ORIG
3-d. Append the contents of
inventory_subelements.txt
cat adva_ethernet_inventory_subelements.txt >> inventory_subelements.txt
Ensure that you use two forward brackets (>>); otherwise, the original contents of
Important:
inventory_subelements.txt will be overwritten.
3-e. Perform a
diff
shown in the following example:
diff inventory_subelements.txt inventory_subelements.txt.ORIG
Netcool/Proviso Adva Optical Metro Ethernet 2.1.1.0 Technology Pack User's Guide, Version 4.3-X
$PVMHOME/bin
tab, then click
Request Editor
tab.
.
button in the
group box to display only idle requests.
Filter
pane, select all idle data collection requests in the following group or
box under
. The Request Editor toggles the idle setting for these data collection
Details
to
in the
idle
active
Active
(
, by default) on the DataMart server:
/opt/datamart/conf
$PVMHOME/conf
adva_ethernet_inventory_subelements.txt
, by entering the following command:
on the backed-up file and the appended file to ensure that the merge succeeded, as
(
/opt/datamart/bin
to open the Request Editor.
column.
, which is installed in the following directory
inventory_subelements.txt
by entering the following command:
to the
$PVMHOME/conf
Appendix A: Configuration
, by default) on the
:
Enter
located in
directory, by
to