Desa TC36NE Series Owner's Operation And Installation Manual page 17

Direct-vent fireplace
Table of Contents

Advertisement

45° Elbow
Venting with Two 90° Elbows
Vertical (V
Note: Vertical (V
) + Vertical (V
1
Figure 23 - Vertical Venting
Configuration Using Two 90° Elbows
(Vertical Round High Wind Termination
Shown)
HIGH ALTITUDE INSTALLATION
Your DESA Heating, LLC direct-vent fireplace
has been tested and approved for elevations
from 0-2000 feet (USA) and elevations from
0-4500 feet (Canada).
When installing this fireplace at an elevation
above 2000 feet (in the USA), you may need
to decrease the input rating by changing the
existing burner orifice to a smaller size. Re-
duce input 4% for each 1000 feet above sea
level. Check with your local gas company for
proper orifice size identification.
116234-01H
VENTING INSTALLATION
Note: Install
restrictor into inner
collar of fireplace
as shown.
) Horizontal (H)
1
5' min.
6' max.
6' min.
12' max.
7' min.
18' max.
8' min.
20' max.
) = 40' max.
2
www.desatech.com
Continued
45° Elbow
Figure 24 - Vertical Venting
Configuration With No Horizontal Run
(Vertical Round High Wind Termination
When installing this fireplace at an elevation
above 4500 feet (in Canada), check with local
authorities.
Consult your local gas company to help deter-
mine the proper orifice for your location.
For assistance with any high altitude instal-
lation contact DESA Heating, LLC' Customer
Service Department at 1-866-672-6040.
Vertical Venting
V = 40' max.
Note: Install restrictor
into inner collar of
fireplace as shown.
Shown)
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtc36ne seriesTc36pe seriesVtc36pe series

Table of Contents