Specifications - Bryant EVOLUTION 987MA Product Data

Modulating 4-way multipose, variable speed condensing gas furnace, series a
Table of Contents

Advertisement

Heating Capacity and Efficiency
Maximum Heat
Intermediate Heat
Input
Minimum Heat
Maximum Heat
Intermediate Heat
Output
Minimum Heat
Efficiency
AFUE % (ICS)
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data
Certified External Static
Pressure (in. w.c.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia. X Width
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
External Control Power
Available
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
Gas Conversion Kit - Natural to Propane
Gas Conversion Kit - Propane to Natural
Manufactured (Mobile) Home Kit
Ignition Device
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections

SPECIFICATIONS

042060
(BTUH)
60,000
(BTUH)
39,000
(BTUH)
24,000
(BTUH)
59,000
(BTUH)
38,000
(BTUH)
24,000
97.0
35 - 65
Maximum Heat
(19-36)
50 - 80
Intermediate Heat
(27-44)
35 -65
Minimum Heat
(19-36)
042060
Heating
0.12
Cooling
0.5
Maximum Heat
1075
Intermediate Heat
530
Minimum Heat
415
Cooling
1335
400 CFM/ton
3
350 CFM/ton
3.5
1/2
7.7
Variable (Communicating)
in.
11 x 8
KGAWF1306UFR
042060
Volts-Hertz-Phase
Min-Max
Amps
9.7
Amps
12.7
AWG
14
Feet
29
(M)
(8.8)
Amps
15
Heating
Cooling
042060
1/2" - NPT
3
Manufacturer
Minimum Inlet Gas
pressure (in. W.C.)
Maximum Inlet Gas
pressure (in. W.C.)
180
2
042080
060100
80,000
100,000
52,000
32,000
78,000
51,000
31,000
97.0
40 - 70
(21-38)
50 - 80
(27-44)
35 - 65
(19-36)
042080
060100
0.15
0.5
1510
750
620
1375
3.5
4
Electronically Commutated Motor (ECM)
1/2
7.7
300 - 1300
11 x 8
Factory Supplied Media Cabinet
Field Supplied Filter
KGAWF1306UFR
KGAWF1406UFR
042080
060100
115-60-1
104-127
9.7
12.7
14
29
(8.8)
15
40 VA
27.9 VA
34.6 VA
042080
060100
4
White Rogers™
4.5
13.6
KGANP5201VSP
KGAPN4401VSP
not approved for MH use
Silicon Nitride
170
Adjustable: 90, 120, 150, 180 seconds
90 seconds
Evolution; Evolution Zoning
W2, Y1, DHUM, G, COM 24V, W/W1, Y/Y2, R
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
066120
120,000
65,000
78,000
40,000
48,000
97,000
117,000
63,000
76,000
39,000
47,000
97.0
97.0
45 - 75
45 - 75
(25-41)
(25-41)
50 - 80
50 - 80
(27-44)
(27-44)
35 - 65
35 - 65
(19-36)
(19-36)
066120
0.20
0.20
0.5
0.5
1515
1815
905
1100
725
900
2030
2185
5
5.5
5.5
6
1
1
12.8
12.8
11 x 10
11 x 11
KGAWF1506UFR
066120
14.8
14.8
19.1
19.1
12
12
30
30
(9.1)
(9.1)
20
20
066120
5
6
160
160

Hide quick links:

Advertisement

Table of Contents
loading