Field Controls 72000 Installation And Owner's Manual

Smart digital humidistat

Advertisement

Quick Links

TB 213
P/N 090375A0213 REV. H 10/2011
R H

General Description

The 072000 is a digital humidifier control
that can automatically adjust the indoor
humidity set point as the outside air
temperature changes. This intelligent
control will maintain accurate humidity
levels and a more comfortable indoor
environment.
The actual indoor relative humidity is
always displayed on the LCD screen. When
the UP or DOWN keys are pressed, the
humidity set point is displayed and can be
adjusted using the UP and DOWN arrow
keys.
An outdoor temperature sensor is included,
and must be connected in order to fully
utilize the features of the 072000. The
outdoor temperature sensor allows the
humidistat to automatically adjust the
humidity set point, to avoid condensation on
windows. It is also a convenient way to read
the outdoor air temperature at any time.
Field Controls Inc. 2630 Airport Road
TECHNICAL BULLETIN
Field Controls Model 072000
Smart Digital Humidistat
Installation and Owner's Manual
O D
% R H
T E M
P
M O D
E
A U T
O
M A N
1
Kinston, NC 28504
®
Copyright © 2011, Field Controls Inc., All Rights Reserved
Package includes:
1 #072000 Smart Humidistat
1 Foam Gasket
1 Mounting Template
1 Technical Bulletin #TB213
2 Mounting screws
2 Wall anchors
1 #OAS Outside Air Sensor
The outdoor sensor is not required to
use the Humidistat in the basic or
manual mode.
The 072000 operates on 24vac, and has
a set of isolated dry contacts for
activating the humidifier. Terminals are
also provided for the Outdoor air
Temperature Sensor. (Part
The 072000 can be installed on the
return air duct or, it can be installed on an
interior wall within the conditioned
space. Field Controls recommends an
interior wall installation. NOTE: If the
return air duct is chosen as the location,
the HVAC fan should be set to run
continuously, in order to obtain an
accurate sampling of the actual living
space relative humidity condition. 3
PH: 252.522.3031
OAS)
#
FAX: 252.522.0214

Advertisement

loading

Summary of Contents for Field Controls 72000

  • Page 1: General Description

    Field Controls Model 072000 Smart Digital Humidistat Installation and Owner's Manual TB 213 P/N 090375A0213 REV. H 10/2011 Copyright © 2011, Field Controls Inc., All Rights Reserved Package includes: 1 #072000 Smart Humidistat 1 Foam Gasket 1 Mounting Template % R H...
  • Page 2 (calling for) humidification. The “RH” symbol remains steady when the humidity set point is satisfied. NOTE: Allow 24 hours for the 072000 to fully stabilize and display the accurate humidity level in your home.
  • Page 3 35°F. Table 2 shows the adjusted RH set The 072000 will display thenew set point p o i n t s f o r d i ff e r e n t o u t d o o r...
  • Page 4 Wiring Diagrams for 072000 Humidistat The diagram below shows the wiring arrangement with an external 24vac transformer To power up the 072000 and the humidifier. Outdoor Temperature Sensor Standard Furnace/Air Handler Thermostat HUMIDIFIER The diagram below shows the wiring for the S-2000 and S-2020 Steam Humidifiers...
  • Page 5: Installation, Wall Mounting

    Use the supplied wall anchors if wall to prevent air leakage from effecting the necessary. RH sensor on the 072000 printed circuit board. Use plumbers putty, wall compound, or even duct tape to seal the hole. Remove the plastic covers...
  • Page 6 After installing and wiring the subbase, attach the 072000 by placing the front over the two top subbase brackets, and swinging the front cover down and snapping it in place. Power up the 072000 after attaching it to the subbase. Front...
  • Page 7 The OAS comes standard with the HK2000 Economizer System and the 072000 Smart Digital Humidity Control. Refer to the HK2000 and the 072000 Technical Bulletins for the specific Outside Air Features & Functions provided, with these products. The OAS is a versatile device because it can be mounted on an outside wall or an outside air duct. See Page 2 & 3.
  • Page 8 FIELD WIRES CONNECTED 46220 10501 TO 072000 OR ZONE PANEL 39917 9298 30*F 8249 34562 30000 7333 26104 6530 22767 5826 INSIDE WALL OUTSIDE WALL CONTROLS INC. Field Controls Inc. 2630 Airport Road Kinston, NC 28504 PH: 252.522.3031 FAX: 252.522.0214...