Bad Case; Left Side Piping; Right Side Piping; Connecting The Installation Pipe And Drain Hose To The Indoor Unit - LG MFL59506845 Installation Manual

Type: wall mounted
Table of Contents

Advertisement

INSTALLATION
12

Bad case

- Following bending case from right to left
directly may cause damage to the tubing.
* The feature can be changed according a
type of model.
!
CAUTION
Installation Information. For right piping.
Follow the instruction above.

Left side piping

Drain hose

Right side piping

!
CAUTION
Method:
1
Disassemble bracket (from indoor unit)
2
Assemble it with conduit
3
Reassemble it with indoor unit.
If the drain hose is routed inside the room
insulate the hose with an insulation mate-
rial* so that dripping from sweating (con-
densation) will not damage furniture or
floors.
* Foamed polyethylene or equivalent is
recommended.
Connecting the installation pipe
and drain hose to the indoor unit.
1
Align the center of the pipes and sufficient-
ly tighten the flare nut by hand
Indoor unit tubing
2
Tighten the flare nut with a wrench
Outside diameter
mm
inch
Ø6.35
1/4
Ø9.52
3/8
Ø12.7
1/2
Ø15.88
5/8
Ø19.05
3/4
Flare nut Pipes
Torque
kgf.m
1.8~2.5
3.4~4.2
5.5~6.5
6.3~8.2
9.9~12.1

Advertisement