Yellow Led Flame Codes; Ignition Module Terminal Cross-Reference; Flash Code Descriptions - Burnham PVG Installation, Operating And Service Instructions

Gas-fired boiler
Table of Contents

Advertisement

H.
Operating Instructions
1. Follow Operating Instructions to place boiler in
operation. See Figure 22.
2. Electronic Ignition Modules with LED indicators.
Table 10 cross-references the ignition module
terminal designations to the ignition terminal
Figure : LED Locations
TABLE 11: Yellow LED Flame Codes
Yellow LED Flash
Code
a
Heartbeat
2
1
OFF

Flash Code Descriptions

a
- Heartbeat: Constant ½ second bright, ½ second dim cycles.
- The flash code number signifies that the LED flashes X times at 2Hz, remains off for two
seconds, and then repeats sequence.
4
Indicates
Normal Flame Signal
Weak Flame Signal -
System will operate reliably but flame signal
is less than desired.
Note: This indication may flash temporarily
during or shortly after lightoff on some
applications.
Marginal Flame Signal (less than 1.1 µA) -
System may not operate reliably over time.
Service call recommended.
Note: This indication may flash temporarily
during or shortly after lightoff on some
applications.
No Flame or Flame Signal -
Below minimum threshold for system
operation.
numbers in the wiring ladder diagrams. The yellow
LED indicates the status of the flame, see Table 11.
The green LED indicates the status of the system,
see Table 12. See Figure 23 for LED locations. See
Figure 24 for Troubleshooting Guide.
Table 10: Ignition Module Terminal
Cross-Reference
Ignition Module
Terminal Designation
MV
MV/PV
PV
GND
24V (GND)
24V
SPARK
Recommended Service Action
Perform routine maintenance to
assure optimum flame signal.
Check gas supply, pilot burner, flame
sense wiring, contamination of flame
rod, burner ground connection.