Check Safety Controls - Carrier 58DFA Installation, Start-Up, And Operating Instructions Manual

120 series downflow induced-combustion sizes 071-135
Table of Contents

Advertisement

PILOT FLAME
MANIFOLD
Fig. 13—Burner Flame
Table 7—Gas Rate Cu Ft/Hr
SIZE OF TEST DIAL
SECONDS
FOR 1
1
2
REVOLUTION
cu ft
cu ft
cu ft
10
360
720
1800
11
327
655
1636
12
300
600
1500
13
277
555
1385
14
257
514
1286
15
240
480
1200
16
225
450
1125
17
212
424
1059
18
200
400
1000
19
189
379
947
20
180
360
900
21
171
343
857
22
164
327
818
23
157
313
783
24
150
300
750
25
144
288
720
26
138
277
692
27
133
267
667
28
129
257
643
29
124
248
621
30
120
240
600
31
116
232
581
32
113
225
563
33
109
218
545
34
106
212
529
35
103
206
514
36
100
200
500
37
97
195
486
38
95
189
474
39
92
185
462
40
90
180
450
41
88
176
439
42
86
172
429
43
84
167
419
44
82
164
409
45
80
160
400
46
78
157
391
47
76
153
383
48
75
150
375
49
73
147
367
a. Place duct thermometers in return and supply ducts as near
furnace as possible. Be sure thermometers do not "see" heat
exchangers so that radiant heat will not affect thermometer
readings. This is particularly important with straight-run
ducts.
BURNER FLAME
BURNER
A84076
SIZE OF TEST DIAL
SECONDS
FOR 1
5
1
2
REVOLUTION
cu ft
cu ft
50
72
144
51
71
141
52
69
138
53
68
136
54
67
133
55
65
131
56
64
129
57
63
126
58
62
124
59
61
122
60
60
120
62
58
116
64
56
112
66
54
109
68
53
106
70
51
103
72
50
100
74
48
97
76
47
95
78
46
92
80
45
90
82
44
88
84
43
86
86
42
84
88
41
82
90
40
80
92
39
78
94
38
76
96
38
75
98
37
74
100
36
72
102
35
71
104
35
69
106
34
68
108
33
67
110
33
65
112
32
64
116
31
62
120
30
60
b. When thermometer readings stabilize, subtract return-air
temperature from supply-air temperature to determine tem-
perature rise.
c. Adjust air temperature rise by adjusting blower speed.
Increase blower speed to reduce temperature rise. Decrease
blower speed to increase temperature rise.
Disconnect the electrical power before changing the speed
tap. A failure to follow this warning could result in personal
injury.
d. To change motor speed taps, remove the motor tap lead and
relocate it on the desired terminal on the plug-in terminal
block/speed selector located on the blower housing. (See
Table 9.)
Table 8—Canadian Orifice Size
GAS
Natural
Propane
SPEED
Common
High
Med-High
5
Med-Low
cu ft
Low
360
355
* White wire from control box to common; black wire from control box to cooling
346
speed selection; red wire from control box to heating and constant fan speed
340
selection.
333
327
321
316
Recheck the temperature rise. It must be within the limits
310
specified on the unit rating plate. Recommended operation is
305
at midpoint of rise or above.
300
290
3. Set thermostat heat anticipator
281
273
The thermostat heat anticipation must be set to match the amp
265
draw of the electrical components in the R-W circuit. Accurate
257
amp draw readings can be obtained at thermostat subbase
250
243
terminals R and W. Fig. 14 illustrates an easy method of
237
obtaining the actual amp draw. The amp reading should be
231
taken after the blower motor has started. See the thermostat
225
220
manufacturer's instructions for adjusting the heat anticipator
214
and for varying the heating cycle length.
209
NOTE: When using an electronic thermostat, set cycle rate for 3
205
200
cycles per hr.
196

CHECK SAFETY CONTROLS

192
188
1. Check operation of gas shut-off control for 100 percent
184
shutoff.
180
178
NOTE: The furnace pilot must be lit so the thermocouple
173
energizes the thermal magnet circuit of gas valve GV, which
170
permits gas flow to the remaining portion of the valve.
167
If the pilot flame is extinguished, the thermocouple will no
164
161
longer energize the thermal magnet circuit of the gas valve.
155
Gas flow to the pilot and main burners will cease until the pilot
150
is manually relit.
a. With furnace operating, unscrew pilot thermocouple lead
from gas valve. The pilot and main burner gas must shut
off. No gas should flow through valve.
b. After valve is found to operate satisfactorily, reconnect
thermocouple to gas valve (fingertight position only).
12
SEA LEVEL
HIGH ALTITUDE
0—2000
2001—4500 FT
44
54
Table 9—Speed Selector
TAP NO.*
45
55
C
1
2
3
4