Flooring; Outdoor Installation - Jandy LRZ Electronic Installation And Operation Manual

Pool and spa heater
Hide thumbs Also See for LRZ Electronic:
Table of Contents

Advertisement

Page 10
Legacy™ Model LRZE Pool/Spa Heater Installation and Operation Manual
Table 2. Minimum Heater Clearances From Combustible Surfaces
Table 2. Dégagements Minimaux à Assurer Entre les Parois de
L'appareil et les Constructions Combustibles
SIDE OF
INDOOR (OUTDOOR
HEATER
SHELTER) INSTALLATION
INCHES
BLANK
8
REAR
6
PIPING
14
TOP
44
FRONT
18*
devices must have a minimum 18" (457mm) clearance
above the À oor.
This heater must be installed at least 5 feet
(1.52m) from the inside wall of a pool unless the
heater is separated from the pool by a solid fence, wall
or other permanent solid barrier.
Ce chauffe-piscine doit être installé au moins 5
pieds (1.52m) de la paroi interne de la piscine à moins
d'être isolé de la piscine par une clôture, un mur ou
autre barrière permanente.
2.3.3

Flooring

The heater must be installed on a level surface
of noncombustible construction or on ¿ re-resistant
slabs or arches. Noncombustible À ooring is de¿ ned
as À ooring material and surface ¿ nish not capable of
being ignited and burning and with no combustible
materials against the underside. Acceptable materials
are those consisting entirely of a combination of steel,
iron, brick, tile, concrete, slate, glass or plaster. Do not
install the heater directly on a combustible wood or
carpet À oor without placing a noncombustible platform
between the À oor and the heater.
The heater can be installed on a combustible
À oor if a noncombustible base assembly, available
from Zodiac Pool Systems, Inc, is used. See the
heater rating plate or the Parts List (Section 11) of this
manual for the appropriate base part number. Heaters
must never be installed directly on carpeting.
As an alternative to the Jandy noncombustible
base plate, in the United States, the National Fuel Gas
Code (NFPA 54 / ANSI Z223.1), and in Canada, the
Natural Gas and Propane Installation Code (CAN/
CSA-B149.1), allow a heater to be placed on a
combustible surface when there is a platform under the
heater made of hollow masonry no less than 4 inches
(102 millimeters [mm]) thick, covered with sheet
metal at least 24 gauge thick and extending beyond the
full width and depth of the heater by at least 6 inches
(153 mm) in all directions. The masonry must be laid
with ends unsealed, and joints matched to provide free
circulation of air from side to side through the
masonry (see Figure 2). If the heater is installed in a
OUTDOOR INSTALLTION
CENTIMETERS
INCHES
20.3
8
15.2
6
35.6
14
111.8
OPEN UNROOFED AREA
45.7*
18*
Note: Clearances listed in Table 2 are
CENTIMETERS
manufacturer's tested values. These are
20.3
given as minimum values. Where local
and national codes apply, and values
15.2
are different than those listed in Table
35.6
2, use the greater value to ensure safe
operation.
45.7*
* In Canada - 24 in (61cm)
Sheet Metal Min.
Thickness 24 Ga
Hollow Concrete Block
Platform (In Canada - Two
continuous courses of
90mm (4 in.) thick hollow
masonry units.)
Notes:
1. Blocks must provide a solid base and be braced so they
cannot slip out of place.
2. Air openings in blocks must be arranged to provide unre-
stricted opening through entire width or length of base.
3. Sheet metal must be at least 24 ga. and extend 6" beyond
the heater jacket on all sides.
Figure 2. Noncombustible Platform
carpeted alcove, the entire À oor of the alcove must be
covered by a noncombustible panel.
2.3.4

Outdoor Installation

The Legacy Model LRZ electronic heater can be
installed in the low-pro¿ le con¿ guration as received
from the factory, or with an optional factory approved
vent cap for high wind applications..
Locate the heater in an open, unroofed area. Do
not install the heater under a deck. Do not locate the
heater below or adjacent to any doors, glass openings,
louvers, grills, etc., which connect in any way with an
inhabited area of a building, even though the access
might be through another structure (e.g., a garage or
utility room). In the United States the vent system shall

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legacy lrz electronic

Table of Contents