Crossover, Equalization And Time-Delay Controller; Amplifier Requirements; Electrical Connection And System Wiring; Flying The X-Array Install Systems - Electro-Voice Xi-1152/64 Instructions Manual

X-array install two-way, full-range, sound-reinforcement system
Table of Contents

Advertisement

X-Array Install™ Xi-1152/64 Loudspeaker System
ties of the loudspeakers. The Dx34 digital
electronic unit was used to provide the
necessary crossover filters and equaliza-
tion during power testing. Specifically, the
Xi-1152/64 passes the ANSI/EIA RS-426-
A power test with the follwing test param-
eters:
Low-Frequency Section:
P
:
E(MAX)
Test Voltages:
R
(1.15 R
):
SR
E
High-Frequency Section:
P
:
E(MAX)
Test Voltages:
R
(1.15 R
):
SR
E
Crossover, Equalization and Time-Delay
Controller
The Xi-1152/64 speaker system and variants
are designed as an integrated package that
utilizes any of the following controllers:
Merlin ISP100, Electro-Voice Dx34 digital
crossover system or Klark-Teknik DN8000.
Optimal performance of the Xi-1152/64
speaker system can only be assured when
using the above referenced controllers.
All controllers used with the Xi-1152/64 fea-
ture a 1,480-Hz crossover frequency utiliz-
ing 24-dB-per-octave Linkwitz-Riley filters.
All contain fixed time delay and equaliza-
tion for optimum performance of the
Xi-1152/64.
Electrical Connection and System
Wiring
Electrical connections to the Xi-1152/64 are
made on the back of the enclosure via a
4-pin conncector. There are two connectors
on the input panel to allow paralleling of
other Xi-1152/64 systems. The Neutrik
Speakon
®
NL4MPR is used for both connec-
tions. The pin assignments are as follows:
Pin 1+: LF(+)
Pin 1-: LF(–)
Pin 2+: HF(+)
Pin 2-: HF(–)
The wiring diagram of the loudspeaker sys-
tem is shown in Figure 7. The electrical im-
2
pedance is shown in Figure 6.

Amplifier Requirements

Power amplfiers with the following ratings
are recommended for use with the
Xi-1152/64 speaker systems:
LF: 600-1,200 watts continuous into 8 ohms
HF: 125-250 watts continuous into 8 ohms
600 watts
Xi-1152/64 speakers may be paralleled only
58.7 volts rms
with other Xi-1152/64 speakers if the am-
117.4 volts peak
plifier is capable of delivering full power at
the lower impedances. The use of amplifi-
5.75 ohms
ers with lower power ratings is acceptable;
however, the full-power capabilities of the
75 watts
Xi speakers will not be realized. The use of
28.46 volts rms
amplifiers with significantly higher power
ratings will generate maximum dynamic
57.8 volts peak
range and fidelity, but care must be utilized
10.8 ohms
for longer duration signals as mechanical and
thermal damage are possible in the system.
Under certain circumstances, higher rated
amplifiers are acceptable. It is acceptable to
drive the Xi-1152/64 speakers with a stereo
power amp utilizing one channel to drive the
low frequencies and the other channel to
drive the high frequencies. See owner's
manuals on various controllers for appropri-
ate settings.
Flying the X-Array Install™ Systems
A manual entitled the X-Array Install™ Fly-
ing Manual is available from Electro-Voice,
and is included with each flying Xi loud-
speaker system. A brief introductory over-
view is included here. The X-Array Install™
Flying Manual should be consulted for com-
plete structural specifications and detailed in-
formation on safely suspending and using the
Xi systems.
The Xi systems incorporate a unique, two-
point flying system that permits a wide range
of vertical angle adjustment, and offers maxi-
mum flexibility in array design for both tour-
ing sound and permanent installations. The
quick release, aircraft-rated, heavy-duty
L-track-type hardware design allows arrays
of loudspeakers to be assembled (and disas-
sembled) very quickly, and offers such
flexibility in the vertical angling of cabinets
that pull-up points are usually unnecessary.
Furthermore, all of the flying Xi loudspeaker
models include the same rigging hardware,
allowing different models to be mixed as
necessary throughout an array.
The working-load limit (for an 8:1 safety fac-
tor) for each rigging point on the Xi loud-
speaker enclosure is 227 kg (500 lb) for a 0°
pull angle and 170 kg (375 lb) for a 90° pull
angle when used with the New Haven
NH32101-2S double-stud fitting, and 113 kg
(250 lb) when used with the New Haven
NH8192-2 or Ancra 42546-10 single-stud
fittings with locking pins. The working-load
limit (for an 8:1 safety factor) for the overall
enclosure is 340 kg (750 lb). (Consult the
X-Array Install™ Flying Manual for specific
structural ratings and limitations.) The en-
closures may be oriented with the rigging
track on the sides of the enclosure, or on the
top and bottom, and may be daisy-chained
together as long as the safety factor is 8:1 or
greater, and local regulations are met. For
fire safety and additional structural strength
in both flying orientations, top-to-bottom
and side-to-side metal straps link the rigging
track inside the enclosure. Electro-Voice
offers a line of
flying-hardware accesso-
ries for use with the Xi loudspeaker systems.
All associated rigging is the responsibility
of others.
CAUTION: The X-Array Install™ loud-
speaker system should be suspended over-
head only in accordance with the proce-
dures and limitations specified in the
X-Array Install™ Flying Manual and
manual update notices.
Field Replacement
The Xi-1152/64 was designed for expedient
field service. Removing the woofer bolts
allows the woofer to be easily removed.
Removing the horn-mounting screws allows
access to the compression driver, both
through the horn and woofer baffle cutouts.
A woofer failure will require replacement of
the entire driver. In the case of a compres-
sion driver failure, a diaphragm assembly
replacement kit with instructions is available.
If desired, the complete driver may be
returned for service.
The following replacement parts are
available from Electro-Voice Service in
Buchanan, Michigan:
LF: Complete woofer: EV Part No. 815-3075
HF: Diaphragm kit; EV Part No. 84233-XX