MHSC SB44SS Installation, Operation And Maintenance Manual page 27

Woodburning outdoor fireplace
Table of Contents

Advertisement

gaS appLIaNCe INSTaLLaTION
7. Pack the insulation removed in step 4 around the pipe to prevent air flowing through
the tube either into or out of the firebox.
8. Be sure the gas is turned off at the appliance, then turn the gas on at the cut off
valve and test the gas line connections for leaks with soapy water solution or a liquid
leak detector. DO NOT USE A MATCH OR OTHER FLAME SOURCE TO CHECK
FOR GAS LEAKS. If a gas leak is detected, turn the gas off immediately and fix the
leak.
9. Proceed with testing the appliance for leaks and adjusting it as required by the
manufacturer instructions.
Figure 30
gas Line plumbing detail
Outer Fireplace Wrap
Inner Fireplace Wrap
Side Brick
Hearth Brick
Gas Line Access Tube
CauTION: When using a gas appli-
ance, the fireplace damper must be
set in fully open position.
appLyINg deCOraTIve TrIM TO The FIrepLaCe
Do not allow the trim materials to extend closer than 3/8 inch to the vertical edges of the firebox
opening if you plan to equip the fireplace with glass doors.
The face of your fireplace may be left exposed or trimmed with any noncombustible material
such as brick, stone or marble. If a trim is installed, be sure it is fastened snugly to the face of
the fireplace. A crack between the material and the face of the fireplace could pose a fire hazard
and impair the proper operation of the fireplace. Blocking the fireplace with framing and attaching
the base to the supporting floor will further reduce the possibility of such a crack developing.
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in
the mortar joints of masonry trim.
Combustible material must not be installed below the top spacers of the fireplace or overlap
the sides of the fireplace face. Seal the face of the fireplace to the surrounding wall with non-
combustible caulk or trim materials to prevent cold air leakage around the fireplace.
The trim should not block or restrict in any way the flow of air into the side air inlets in the face
of the fireplace.
Be sure to provide the required floor protection as described in a preceding section of this
manual.
Combustible mantels and trim must be installed in accordance with the National Fire Protection
Association - ANSI NFPA 11 Standard - Section 7-.3.3.
87D0059
Maintain 1/" Minimum Air Space
Clearance to Combustibles for
Gas Line Out to 4" From Side of
the Fireplace
Combustible Materials May Be Lo-
cated at Zero Clearance to Gas Line
Beyond 4" From Fireplace Side.
Repack Insulation Around
Gas Line Where it Passes
Through Gas Line Access
Tube for Proper Seal
FP2232
gas line installation
1/09
SB44SS Outdoor Woodburning Fireplace
Back Brick
Knockout
Side Brick
FP3
7