Desa TC36N Series Owner's Operation And Installation Manual page 28

Direct-vent fireplace natural, propane gas
Table of Contents

Advertisement

OPERATION
Continued
6. The pilot is located by the main burner and
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT (see Figure 45)
8. Push in gas control knob all the way and
hold. Immediately light pilot by repeatedly
pressing the piezo spark ignitor until a
flame appears. Continue to hold for about
one (1) minute after pilot is lit. Release
gas control knob and it will pop back. Pilot
should remain lit. If it goes out, repeat
steps 5 through 8.
• If gas control knob does not pop up when
released, stop and immediately call your
service technician or gas supplier.
• If pilot will not stay lit after several tries,
turn gas control knob to OFF and call
your service technician or gas supplier.
9. Turn on all electric power to fireplace.
10. Turn gas control knob counterclockwise
to ON.
11. This valve is equipped with a HI/LO fea-
ture. Set fireplace input as desired.
12. To turn off burners and leave pilot lit,
turn gas control knob clockwise
PILOT position. Set selector switch in the
OFF position.
13. Close lower louver panel.
Gas Control
Knob
Piezo
Ignitor
Figure 45 - Control Valve
TO TURN OFF GAS
TO APPLIANCE
1. Open lower louver panel.
2. Set selector switch in the OFF position to
prevent draining battery.
3. Turn off all electrical power to appliance
if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
5. Close lower louver panel.
28
Variable Control Knob
to OFF.
www.desatech.com
MANUAL LIGHTING
1. Remove glass door (see Removing/Re-
placing Glass Door, page 25).
2. Follow steps 1 through 8 under Lighting
Instructions, page 27.
3. Press gas control knob and light pilot with
match.
4. Keep gas control knob pressed in for
30 seconds after lighting pilot. After 30
seconds, release gas control knob. Fol-
low steps 9 through 12 under Lighting
Instructions.
5. Replace glass door (see Removing/Re-
placing Glass Door, page 25).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must
be purchased separately (see Accessories,
page 42). Follow instructions included with
the remote control.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions, page 27.
to
After lighting, let pilot flame burn for about one
minute. Turn control knob to the ON position.
Adjust flame adjustment knob anywhere be-
tween HI and LO. Slide selector switch to the
REMOTE position (see Figure 46).
Note: The burner may light if hand-held re-
mote was on when selector switch was last
turned off. You can now turn burner on and off
with hand-held remote control unit.
IMPORTANT: Do not leave selector switch in
the REMOTE or ON position when pilot is not
lit. This will drain the battery.
Blower Control Knob
(Optional Accessory)
Selector Switch in
Remote Position
Figure 46 - Setting Selector Switch, Gas
Control Knob and Variable Control Knob
for Remote Operation
PROCEDURE
Variable
Control Knob
OFF
ON
Gas Control Knob
in ON Position
116192-01M

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc36p seriesVtc36n seriesVtc36p series

Table of Contents