Operating Instructions
CAUTION: BEFORE USING THE ALARM HUSH FEATURE,
!
IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A
SAFE CONDITION EXISTS.

Reset Feature

If the the Smoke/CO Alarm is sounding a CO alarm, pressing the
test/reset button will silence the alarm.
If the CO condition that caused the alert continues, the alarm will
reactivate within 200 seconds (follow the action plan on page
20).
CO Peak Level Memory
If the green LED is blinking once every 10 seconds, the unit has
detected a hazardous CO condition. If the CO sensor has detected a
CO level of 100 PPM or higher since last reset, it will be recorded by
the Peak Level Memory function. To access the Peak Level Memory
press the test/reset button. If a reading of 100 PPM or higher has
been recorded, the unit will announce "Carbon Monoxide Previously
Detected." If you've been away from home this feature allows you
to check if there was a CO reading of 100, or higher, during your
absence. Pushing the test/reset button resets the memory. It's also
reset when the power is removed. Note: the green LED blinking
portion of CO Peak Level Memory is disabled when the unit is on
battery power only.

LED Indicator Operation

Red LED
The red LED will flash as described below under the following
conditions:
--During smoke or CO alarm, with every beep
--During testing (same as alarm)
--Low battery, single flash with chirp
--End of product life, double flash every 30 seconds with chirp
--Unit error mode, single flash with chirp
--Unit error mode, a Fault Code is flashed every 30 seconds (can
be observed and reported to customer service for
troubleshooting).