FIGURE 17.
6.
The buss bar is labeled 5500 W. Place the buss bar over
terminals 2 and 3 with the 5500 W visible. Install the extra
screw provided into terminal 3.
FIGURE 18.
7.
The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
FIGURE 19.
8.
Tighten terminals 2 and 3 to ensure proper electrical
connection.
failure to tighten terminal screws can cause a fire which can
result in dEATH, SErIouS bodIly INjury, or ProPErTy
dAMAGE.
9.
replace terminal cover on thermostat making sure that the
locking tabs on the terminal cover are in place.
Make sure the thermostat is flush against the tank, the terminal
cover is in place, and the insulation is replaced. failure to
do so can result in dEATH, SErIouS bodIly INjury, or
ProPErTy dAMAGE.
10. replace the insulation block so that it completely covers the
thermostat and element.
11. replace the access panel.
12. Complete wiring to the water heater, or if completed, turn
"oN" electric power to the water heater after filling the tank
with water.