Kenwood TKR-850 Service Manual page 43

Uhf fm repeater
Hide thumbs Also See for TKR-850:
Table of Contents

Advertisement

TKR-850
Item
Condition
12. TX RF
1) Measure the power level at
low power
TX ANT.
Low CH
2) Center CH
3) High CH
13. BPF
1) Connect the TG to RX ANT,
then connect CN1 to the
spectrum analyzer input.
Spectrum analyzer setting
Span : 50MHz
Scale : 10dB to 5dB div
Tracking generator setting
Output : –30dBm
14. MCF
1) Connect the TG to CN2, then
(Wide)
connect CN4 to the spectrum
analyzer input.
CH : 2 (Wide)
Spectrum analyzer setting
Span : 50kHz to 25kHz
Scale : 10dB to 2dB div
Center freq' : 44.850MHz
Tracking generator setting
Output : –30dBm
(Narrow)
2) CH : 2 (Narrow)
15. Discrimi-
1) Connect the SSG to RX ANT. SSG
nator
CH : 2 (Wide)
SSG output : –53dBm/501µV
SSG MOD : 1kHz
SSG DEV : 3kHz
AF : 2V/4Ω
16. Threshold
1) Connect SSG to RX ANT.
squelch
CH : 2 (Wide)
(Wide)
SSG output : 3dB below to
12dB SINAD level
SSG MOD : 1kHz
SSG DEV : 3kHz
AF : 2V/4Ω
2) SSG : OFF
(Narrow)
3) CH : 2 (Narrow)
SSG output : 3dB below to
12dB SINAD level
SSG MOD : 1kHz
SSG DEV : 1.5kHz
AF : 2V/4Ω
4) SSG : OFF
44
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
TX ANT
Tracking
Rear
RX ANT TX-RX L2
generator
(A/2)
Spectrum TX-RX CN1
analyzer
(A/2)
CN2
CN4
Rear
RX ANT
AF VM
TEST/SPKR
Distortion
jack SPO
meter
(pin 12)
SSG
Rear
RX ANT
Audio
TEST/SPKR
analyzer
jack SPO
VTVM
(pin 12)
Oscilloscope
Adjustment
Parts
Method
± 1W
PC adj.
25W
(Shipping power)
Center the frequency
L4
you are using, then
L5
adjust it to look like
the wave Fig. 1.
(Page 48)
L14
Adjust it to look like
L17
the wave Fig. 2.
L18
(Page 48)
L15
Adjust it to look like
L16
the wave Fig. 3.
L19
(Page 48)
L24
Adjust the distortion
to minimum.
PC adj.
Adjust to point of
opening squelch
Check
Squelch must be closed.
PC adj.
Adjust to point of
opening squelch
Check
Squelch must be closed.
Specifications/Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents