Pentair SSJ Series Owner's Manual

Vertical jet pumps

Advertisement

Quick Links

OWNER'S MANUAL
Vertical Jet Pumps
2875 0697ASB
"SSJ" Series
Installation/Operation/Parts
For further operating, installation,
or maintenance assistance:
Call 1-888-782-7483
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM
PH: 888-782-7483
S724 (REV 01/14/13)
© 2013 Pentair Ltd. All Rights Reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Pentair SSJ Series

  • Page 1 OWNER’S MANUAL Vertical Jet Pumps 2875 0697ASB “SSJ” Series Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-888-782-7483 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM PH: 888-782-7483 S724 (REV 01/14/13) © 2013 Pentair Ltd. All Rights Reserved.
  • Page 2: General Safety

    Safety READ AND FOLLOW ELECTRICAL SAFETY SAFETY INSTRUCTIONS! Capacitor voltage may be hazardous. To discharge motor capacitor, hold insulated handle This is the safety alert symbol. When you see this screwdriver BY THE HANDLE and short capacitor symbol on your pump or in this manual, look for one of terminals together.
  • Page 3: Table Of Contents

    Table of Contents Thank you for purchasing a top quality, factory tested pump. Page General Safety .....................2 Warranty......................3 Installation ......................4-6 Electrical ......................7,8 Operation .......................9,10 Maintenance ....................10-12 Repair Parts ....................13,14 Troubleshooting ....................15 Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below.
  • Page 4: Warranty

    Installation BEFORE YOU INSTALL YOUR PUMP Pump Pump NOTICE: For proper performance, pump MUST be matched to ejector and Gasket Gasket to well depth. This pump is designed for wells from 25 ft. to 130 ft. depth Adapter Flange Adapter Flange from well head to water.
  • Page 5 Installation 7. Install enough plastic pipe in well casing to put ejector at the proper Pump depth. (Ask your well driller for this information.) mounted on Casing IMPORTANT: As a guide, the ejector should be set at least 10 to 20 feet Adapter below the lowest water level with pump running, if possible, but always at least five feet from the bottom of the well.
  • Page 6 Installation DISCHARGE PIPE SIZES 1. If increasing discharge pipe size, install reducer in pump discharge port. Standard Tank Do not increase pipe size by stages. 2. When the pump is set away from the points of water use, the discharge Air Volume pipe size should be increased to reduce pressure losses caused by Control...
  • Page 7: Electrical

    Electrical Disconnect power before working on pump, motor, pressure switch, or wiring. MOTOR SWITCH SETTINGS NOTICE: 1/2 HP motors are wired for 115 volts only, and have no motor wiring to change. Your motor terminal board (located under the motor end cover) should look like one of those below. If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts.
  • Page 8: Electrical

    Electrical Hazardous voltage. Can shock, burn, or kill. Connect ground wire before connecting power supply wires. Use the wire size (including the ground wire) specified in the wiring chart. If possible, connect the pump to a separate branch circuit with no other appliances on it. Explosion hazard.
  • Page 9: Operation

    Operation PRIMING THE PUMP NEVER run pump dry. Running pump without water may cause pump to overheat, damaging seal and possibly causing burns to persons handling pump. Fill pump with water before starting. NEVER run pump against closed dis charge, to do so can boil water inside pump, causing hazardous pressure in unit and possibly scalding persons handling pump.
  • Page 10 Operation / Maintenance 4. Once unit has primed and pressure stabilized, slowly open (turn counterclockwise - Figure 15) regulator valve until pressure falters (pressure gauge needle flutters; pump may become noisy - see Figure 16). At this point, close (turn clockwise) regulator valve slightly until pressure stabilizes.
  • Page 11: Maintenance

    Maintenance PUMP DISASSEMBLY The seal consists primarily of two parts: a rotating member and a floating seat. The highly polished and lapped faces of the seal are easily damaged. Read instructions and handle the seal with care. 1. Be sure disconnect switch is off. 2.
  • Page 12 Maintenance HOW TO HANDLE A GASEOUS WELL Be Careful That ...Does Not Damage Motor Shaft Shoulder... Seal Face In some areas well water contains gases which must be allowed to escape before the water is used. To deliver gas-free water suspend a pipe, closed at the bottom and open at the top, so that it surrounds the suction pipe inlet.
  • Page 13: Repair Parts

    Repair Parts 2365 0396 REPAIR PARTS LIST REF. MODEL DESCRIPTION J212-19E QTY. Adjusting Screw, 1/4x20x3/4” U30-537ZP Spring Follower J24-7 Diaphragm J20-5 Valve Guide J42-4 Diaphragm and Valve Guide Assembly J120-14 Valve Seat Only J66-15 Regulator Body with Valve Seat J112-8E 1/2x1/8”...
  • Page 14: Repair Parts

    Repair Parts 2875 0697 REPAIR PARTS LIST MODEL AND HORSEPOWER REF. SSJC SSJD SSJE DESCRIPTION 1/2 HP 3/4 HP 1 HP QTY. Motor Canopy J18-59 J18-59 J18-59 Motor A200CH A200DH A200EH Adapter L2-8B L2-8B L2-8B 3/8-16x1” Capscrews U30-74ZP U30-74ZP U30-74ZP Shaft seal U109-6A U109-6A...
  • Page 15: Troubleshooting

    Troubleshooting SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Motor will not run Disconnect switch is off Be sure switch is on. Fuse is blown or circuit breaker tripped Replace fuse or reset circuit breaker. Starting switch is defective DISCONNECT POWER; Replace starting switch. Wires at motor are loose, Refer to instructions on wiring (Pages 7 and 8).