Troubleshooting; Fishfinder Doesn't Power Up; Fishfinder Defaults To Simulator With A Transducer Attached - Humminbird 500 SERIES 580 Operation Manual

Fishfinder fishfinder
Table of Contents

Advertisement

Troubleshooting

Before contacting the Humminbird® Customer Resource Center, please read the
following section. Taking the time to review these troubleshooting guidelines
may allow you to solve a performance problem yourself, and therefore avoid
sending your unit back for repair.

Fishfinder Doesn't Power Up

If your Fishfinder doesn't power up, use the Installation Guide that also comes with
it for specific confirmation details, making sure that:
• The power cable is properly connected to the Fishfinder control head.
• The power cable is wired correctly, with red to positive battery terminal and
black to negative terminal or ground.
• The fuse is operational.
• The battery voltage of the power connector is at least 10 Volts.
Correct any known problems, including removing corrosion from the battery
terminals or wiring, or actually replacing the battery if necessary.

Fishfinder Defaults to Simulator with a Transducer Attached

A connected and functioning transducer will cause the newly-started Fishfinder to go
into Normal operating mode automatically. If, when you power up the Fishfinder, it
goes into Simulator mode automatically, even though a transducer is already
connected, this means that the control head is not detecting the transducer. Perform
the following troubleshooting tasks:
• Using the Installation Guide that also comes with your Fishfinder, check to
make sure that the transducer cable is securely connected to the Fishfinder.
Reconnect if necessary, and power up the Fishfinder again to see if this
fixes the problem.
• Replace the non-functioning transducer with a known good transducer if
available and power up the control head again.
• Check the transducer cable. Replace the transducer if the cable is damaged
or corroded.
94

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

580