Vermont Castings ODGSR36A Homeowner's Installation And Operating Manual

Outdoor gas fireplace

Advertisement

Quick Links

Outdoor Gas Fireplace
Models:
ODGSR36A, ODGSR42A
INSTALLER/CONSUMER

SAFETY INFORMATION

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing
this equipment.
WARNING:
For Outdoor Use ONLY.
Homeowner's Installation and
Operating Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
7114
ODGSR
cover
11/03
20007114 10/13 Rev. 17

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings ODGSR36A

  • Page 1: Safety Information

    Outdoor Gas Fireplace Models: ODGSR36A, ODGSR42A INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    ODGSR Series Outdoor Gas Fireplace Table of Contents Thank you and Congratulations on your purchase of a Vermont Castings Group fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Installation & Operating Instructions

    ODGSR Series Outdoor Gas Fireplace General Information This gas appliance should be installed by a qualified in- Enclosures for LP-Gas Supply Systems staller in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Enclosures for LP-gas supply cylinders shall be ventilated by openings at the level of the cylinder valve and at floor level. The Appliances and Equipment. effectiveness of the opening(s) for purposes of ventilation shall FOR U.S.A Installations follow local codes and/or the cur- be determined with the LP-gas supply cylinder(s) in place. This...
  • Page 4: Fireplace Dimensions

    3 " (210mm) (95mm) 14 " 40" 3 " 3 " " (362mm) (1016mm) (95mm) (98mm) (165mm) Gas Line Access Fig. 1 ODGSR36A specification and framing dimensions. Fireplace Dimensions 7114 " ODUVSR36A (667mm) Specs Rough 11/03 Opening Depth 50" (1270mm) " (13mm) " (572mm) 22"...
  • Page 5: Moisture Resistance

    ODGSR Series Outdoor Gas Fireplace Moisture Resistance Mantels This outdoor fireplace will shed moderate amounts of wa- WARNING: A 4" hood must be used if a mantel ter, but is not waterproof. Water and condensing water is to be installed. vapor may enter the chase under certain conditions. The height that a combustible mantel is fitted above the The fireplace will not perform as an exterior wall. Mois- fireplace is dependent on the depth of the mantel. This also ture penetration must be considered for construction that applies to the distance between the mantel leg (if fitted) places the fireplace in structure walls or on moisture sen- and the fireplace. sitive surfaces. For the correct mounting height and widths refer to Figures When installed on exterior walls: Vermont Castings 3a and 3b Group recommends the fireplace chase be constructed outside the structure's weather envelope. Where the plat-...
  • Page 6: Moisture Resistance

    ODGSR Series Outdoor Gas Fireplace Hearths should slope away from the front of the fireplace and chase at 1/8 in to 1/4 in per foot. Metal safety strips must be on top of any combustible hearth materials used for moisture management. Framing and Finishing Black Check appliance to make sure it is levelled Mantel Surround and properly positioned. Face CFM164 The appliance should only be mounted on the following surfaces: Side of CFM164a Combustion Chamber Mantel Leg Chart • A flat combustible (burnable) surface. 06/22/01 sta •...
  • Page 7: Gas Specifications

    5.5” w.c. 11.0” w.c. Fig. 5 Valve access. Maximum Inlet Pressure 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5”w.c. 10.0” w.c. FP1414 ODUVSR valve access ODGSR36A / ODGSR42A 11/24/03 djt Certified to ANSI Z21.97 Outdoor Decorative Gas Appliances Vermont Cast- CGA CR97-003 ings Group Logo Brick Outdoor Gas Fireplaces FP1415 Fig. 6 Lift brick with logo on it to access valve. High Elevations...
  • Page 8: Exterior Chase Installation

    ODGSR Series Outdoor Gas Fireplace Gas Line Installation *Do not install header until unit is in place. This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure equal to or less than 1/2 psig (3.45 kPa). The appliance and its individual shutoff valve must be dis- Standoff Surround connected from the gas supply piping system during any pressure testing of that system at test pressures in excess Gas of 1/2 psig (3.45 kPa). Nailing Line Ac- Flange cess If gas piping from the source to the appliance location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size. Screen The gas pipeline can be brought in through the right side of the appliance. A knockout is provided to allow for the gas Grate pipe installation and testing of any gas connection. Firebox NOTE: The gas line connection can be made with 3/8" Valve Access Panel copper tubing approved for propane or natural gas, 1/2"...
  • Page 9: Remote Wall Switch

    ODGSR Series Outdoor Gas Fireplace Remote Wall Switch NOTE: Use an approved outdoor switch. Pilot 1. Thread wire through the low voltage wire access hole located on either side of unit. Do not cut wire or insula- tion on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box. 2. Attach wire to switch and install switch into receptacle Thermodisk box. Attach cover plate to switch. 3. Connect wiring to gas valve. Refer to Figure 11. CAUTION: Do not wire millivolt remote wall switch for gas appliance to a 120v power supply. For lighting instructions, refer to Page 12. Valve NOTE: If glass doors are installed, the unit must be operated with the doors fully open.
  • Page 10: Operating Instructions

    ODGSR Series Outdoor Gas Fireplace Operating Instructions Log Installation Right Cross 1. Remove logs from the packaging. As with all plastic, these bags Left Cross are not toys and should always be kept away from children and infants. 2. Place left rear log on rear log support. Right Rear Ensure that log is firmly positioned and there is no side-to-side movement. (Figs.
  • Page 11: Flame Adjustment

    FP581 flame height Fig. 16 Proper pilot flame height. Fig. 15 Flame adjustment knob for SIT820 valve. FP581 Flame Characteristics FP390 NVB-PILOTS FLAME ADJUSTMENT KNOB It is important to periodically perform a visual check of the 12/4/97 11/21/96 pilot and the burner flames. Compare them to the illustra- tions below (Figs. 16, 17, 18). If any of the flames appear abnormal call a service person. Red Glow LG319 Fig. 17 ODGSR36A flame appearance. LG319 ODUVSR36 log flames 11/24/03 djt LG320 Fig. 18 ODGSR42A flame appearance. 20007114...
  • Page 12: Optional Weather Enclosures

    ODGSR Series Outdoor Gas Fireplace Optional Weather Enclosure Optional Stainless Steel Hood An optional weather enclosure is available to protect the An optional stainless steel hood is available for both the burner when not in use. ODGSR36A and ODGSR42A. CAUTION: Do not use the weather enclosure if NOTE: The stainless steel hood may NOT be the unit has glass doors installed. used when the optional glass doors are in- stalled. Installation Instructions Installation Instructions: 1. Turn the unit OFF and allow to cool.
  • Page 13: Lighting & Operating Instructions

    ODGSR Series Outdoor Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- • If you cannot reach your gas supplier, call the ally. When lighting the pilot follow these Fire Department...
  • Page 14: Troubleshooting

    ODGSR Series Outdoor Gas Fireplace Troubleshooting Nova SIT 820 Standing Pilot START CHECK Supply Line Hooked up Gas Supply On Shutoff Valve Open Lockout has engaged. Wait 60 seconds and try again. Piezo not tight enough for good ground. Pilot Lights with For spark at electrode while Piezo Ignitor depressing Piezo (Red Button)
  • Page 15: Maintenance

    ODGSR Series Outdoor Gas Fireplace Maintenance Burner and Burner Compartment Cleaning the Standing Pilot It is important to keep the burner and the burner compartment Control System clean. At least once per year the logs should be removed The burner and control system consists of: and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in • main burner this manual. •...
  • Page 16 ODGSR Series Outdoor Gas Fireplace 1. ODGSR36A Logs 1. ODGSR42A Logs 4a/b 12a/b 19a/b 7114 18a/b Vermont Castings Group reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODGSR36A, ODGSR42A Ref. Description ODGSR36A ODGSR42A 1. Logs - Complete Set 20007180 20007200 1a. Log - Left Rear 20007175 20007193 1b. Log - Right Rear 20007176 20007194 1c. Log - Right Cross 20007178 20007197 7114 oduvsr36/42A 1d. Log - Left Cross...
  • Page 17: Replacement Parts

    ODGSR Series Outdoor Gas Fireplace ODGSR36A, ODGSR42A (continued) Ref. Description ODGSR36A ODGSR42A 14. Pilot Tubing 10001296 10001296 15. Cable Ignitor 24" 7522432 7522432 16. Thermocouple 24" 7531137 7531137 17. Grate 20006819 20006819 18a. Pilot Orifice - Natural 10002268 10002268 18b. Pilot Orifice - LP 10002269 10002269 19a. Valve NOVA - Natural 7529141 7529141 19b. Valve NOVA - LP...
  • Page 18: Accessories

    Group approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the Vermont Castings Group warranty. In addition, such action may void the coverage provided by the owner's insurance.
  • Page 19: Warranty

    LIMITED LIFETIME WARRANTY ODGSR Series Outdoor Gas Fireplace PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Monessen and Vermont Castings Group brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard BASIC WARRANTY parts and/or labor. Vermont Castings Group (hereinafter referred to collectively as the • Any part and/or component replaced under the provisions of this Company) warrants that your new Vermont Castings, Monessen warranty is covered for six months or the remainder of the original or Vermont Castings Group Gas Fireplace/Stove is free from warranty, whichever is longest.
  • Page 20 Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...

This manual is also suitable for:

Odgsr42a

Table of Contents