HP Pressure Booster Pumps 0306 Operating Instructions And Parts Manual
HP Pressure Booster Pumps 0306 Operating Instructions And Parts Manual

HP Pressure Booster Pumps 0306 Operating Instructions And Parts Manual

Pressure booster pumps

Advertisement

Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per-
sonal injury and/or property damage! Retain instructions for future reference.
Pressure Booster Pumps
Description
Pressure booster pumps increase water pressure from city mains or private water sys-
tems. Applications include providing high water pressure for washing buildings, dairy
walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn
sprinkling and insecticide spraying. Stainless steel models can handle salt-water and
contaminated water in reverse osmosis filter and other aggressive water applications.
Single-phase models are equipped with a capacitor start, thermal protected motor.
Three-phase models require separate overload protection.
60 Hz Motor Driven Pump Dimensions (See Figure 1) •
Stainless
Powder-Coated
Steel Fitted
Cast Iron Fitted
PB0508S031
PB0508C031
PB0512S051
PB0512C051
PB0516S071
PB0516C071
PB0712S071
PB0712C071
PB1014S101
PB1014C101
PB1016S151
PB1016C151
PB1914S201
PB1914C201
PB2711S201
PB2711C201
PB3506S201
PB3506C201
PB2714S301
PB2714C301
PB3508S301
PB3508C301
-
-
-
-
-
-
-
-
50 Hz Motor Driven Pump Dimensions (See Figure 1) •58
PB0508Y031
-
PB0514Y051
-
PB0714Y071
-
PB1020Y101
-
PB1023Y101
PB1023Z101
PB2717Y201
-
-
-
PB1021Y101
-
PB1920Y151
-
-
PB1922Z201
(*) NOTE: Figure 1, holes in mounting base are open slotted 3/8" wide x 1/2" long; dimension A & B are centerline from these
open slotted holes. These holes are suitable for 1/4 to 3/8" bolts.
Dimensions also apply to three phase models.
(
†) Equipped with carrying handle. 132079 handle available as an option on other models. Add 1-3/8" to "G" if handle is included.
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
H
G
A
Figure 1
Cast Iron
Fitted
A
B
PB0508A031†
3-1/4
3-3/4
PB0512A051†
3-1/4
3-3/4
PB0516A071
3-1/4
3-3/4
PB0712A071
3-1/4
3-3/4
PB1014A101
3-1/4
3-3/4
PB1016A151
3-1/4
3-3/4
PB1914A201
3-1/4
3-3/4
PB2711A201
3-1/4
3-3/4
PB3506A201
3-1/4
3-3/4
PB2714A301
3-1/4
3-3/4
PB3508A301
3-1/4
3-3/4
PB5504A201
3-1/4
3-3/4
PB5506A301
3-1/4
3-3/4
PB8504A201
3-1/4
3-3/4
PB8505A301
3-1/4
3-3/4
PB0508X031
3-1/4
3-3/4
PB0514X051
3-1/4
3-3/4
PB0714X071
3-1/4
3-3/4
PB1020X101
3-1/4
3-3/4
PB1023X101
3-1/4
3-3/4
-
3-1/4
3-3/4
PB3508X151
3-1/4
3-3/4
-
3-1/4
3-3/4
-
3-1/4
3-3/4
-
3-1/4
3-3/4
Inlet I
Discharge J
C
F
Dimensions In Inches
C
D
E
F
10-3/16
3-7/8
6-1/2
19-15/16
13-3/8
3-7/8
6-1/2
23-3/8
16-1/2
3-7/8
6-1/2
27
13-3/8
3-7/8
6-1/2
23-7/8
16-5/16
3-7/8
6-1/2
27-1/4
17-5/8
3-7/8
6-1/2
29-3/16
18-1/8
3-7/8
6-1/2
29-11/16
15-3/8
3-7/8
6-1/2
27-1/2
13-15/16
3-7/8
6-1/2
25-7/8
18-1/2
3-7/8
6-1/2
30-9/16
17-1/8
3-7/8
6-1/2
29-3/16
13-3/4
3-7/8
6-1/2
25-15/16
18-1/16
3-7/8
6-1/2
30-3/16
16-1/2
3-7/8
6-1/2
28-5/8
19-5/16
3-7/8
6-1/2
31-1/2
10-3/16
3-7/8
6-1/2
20-3/16
14-7/16
3-7/8
6-1/2
25-7/16
14-15/16
3-7/8
6-1/2
25-15/16
21-11/16
3-7/8
6-1/2
33-5/16
24-3/8
3-7/8
6-1/2
36
21-5/16
3-7/8
6-1/2
33-7/16
16-13/16
3-7/8
6-1/2
29-11/16
22-1/2
3-7/8
6-1/2
34-3/16
24-1/16
3-7/8
6-1/2
34-3/8
26-1/8
3-7/8
6-1/2
37-3/16
1
Unpacking
When unpacking the unit, inspect care-
fully for any damage that may have
occurred during transit.
NOTE: Use pump with clear water
only.
D
B
E
IL0391
Chart A
G
H
I
J
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
1
1
7-3/8
1-7/16
1
1
7-3/8
1-7/16
1
1
7-3/8
1-7/16
1
1
7-3/8
2-1/8
2
2
7-3/8
2-1/8
2
2
7-3/8
2-1/8
2
2
7-3/8
2-1/8
2
2
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
1
1
7-3/8
1-7/16
1
1
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
7-3/8
1-7/16
3/4
3/4
132934
FW0154
0907
Supersedes
0306
Lbs. Ship
Wt.
35
38
43
42
48
51
51
52
51
54
53
57
57
58
58
34
41
47
53
55
56
52
54
56
59

Advertisement

Table of Contents
loading

Summary of Contents for HP Pressure Booster Pumps 0306

  • Page 1 Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per- sonal injury and/or property damage! Retain instructions for future reference.
  • Page 2: Performance Specifications

    To keep pump and seal lubricated, a minimum flow of 1.5 GPM must always be maintained through the pump. Motor voltage: Single Phase 1/3 - 2 HP - 115/230; 3 HP - 230V 60 Hz. Three Phase 1/2 - 2 HP - 208-230/460, 50/60Hz.
  • Page 3 230V 208-230/460 230V 1-1/2 208-230/460 230V 208-230/460 230V 3✝✝ 208-230/460 230V ✝✝3 HP, 3 Phase motor operable on 60Hz only. Material Construction Component Motor Bearings Impellers Diffuser Diffuser plates Pump shaft Pump shaft coupling Pump shell Discharge & inlet casting...
  • Page 4 General Safety Information Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. Replace missing or damaged safety labels. This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump or in the manual, look for one of the following signal words and be alert to the potential for per- sonal injury or property damage.
  • Page 5: Pump Installation

    Installation PUMP INSTALLATION IMPORTANT: Pump is built to handle clear water only; it is not designed to handle water containing sand, silt or other abrasives. 1.Refer to Figures 6, 7, and 8 for typi- cal installations. Support pump and piping when assembling and when installed.
  • Page 6 Installation (Continued) 5. A pressure gauge installed in the inlet pipe close to the inlet port, (See Figure 6) will show if enough water is being supplied to the pump. See Operation Section - Priming, Pressure Boost Installations. 6. On installations that are using noz- zles for mist spraying, install a filter in the discharge plumbing to prevent the nozzles from becoming plugged.
  • Page 7 115 Volts Single Phase Line NOTE: Dual voltage motors, change the red and gray wire to the voltage required. Figure 9 - Wiring Diagram for Single Phase 1/3 - 2 HP Motors 230 Volts Single Phase Line NOTE: Single voltage (230V) motor, and can not be connected to 115V.
  • Page 8: Motor Protection

    Select the voltage you are to use, either 115V or 230V single phase, 230V or 460V three phase. b. The 1/3, 1/2 and 3/4 HP single phase pumps are factory connected for 115V at the motor. The 1, 1 HP pumps are factory connected for 230V at the motor.
  • Page 9 Operation (Continued) MOTOR/PUMP ROTATION 1. Single phase models are one (1) rotation only (counter- clockwise when facing the pump end) and cannot be reversed. 2. Proper rotation of pump impeller is critical for three phase pumps. Pump motor should turn counterclockwise (CCW) when facing pump end.
  • Page 10: Motor Replacement

    MOTOR REPLACEMENT The motor can be replaced with any standard Nema 56J jet pump motor (of proper HP for each pump) by referring to the following instructions. 1. Follow steps as outlined under Rotary Seal Replacement and Pump Disassembly.
  • Page 11: Troubleshooting Chart

    Troubleshooting Chart Symptom Possible Cause(s) Pump won’t 1. Blown fuse or open circuit breaker start or run at full speed 2. Power supply in OFF position 3. Incorrect voltage at motor (check volt- age with motor running) 4. Loose, broken or incorrect wiring 5.
  • Page 12 Booster Pump Parts Drawing ITEM NO. DESCRIPTION Motor †Governor †Switch Motor Seal, Rotary Barrel Discharge Head Discharge Bearing O-ring (2) Plate, Diffuser Impeller Diffuser Diffuser Bearing Shim as Required Shaft and Coupling Assembly Mounting Ring Hex Head Bolts (4) †MotorAccess Cover †Screws, Access Cover (2) *See note below parts included in cartridge assembly.
  • Page 13 PRESSURE BOOSTER PUMP REPAIR PARTS (For Pricing Refer To Repair Parts Price List) ITEM REPLACEMENT MOTORS ODP NEMA J 1/3 HP ODP NEMA J 1/2 HP ODP NEMA J 3/4 HP ODP NEMA J 1 HP ODP NEMA J 1-1/2 HP...
  • Page 14 PRESSURE BOOSTER PUMP REPAIR PARTS FORM NO. FW0046 0907 (For Pricing Refer To Repair Parts Price List) SUPERSEDES 0206 PAGE 4-8A REPAIR PARTS ITEM Discharge Head 3/4” NPT 5 - 7 - 10 - 19 GPM, Mounting Ring 3/4” NPT 60 HZ &...

Table of Contents