Blue Rhino WUSB-150 User Manual

Lp gas outdoor fire bowl

Advertisement

DANGER
• This appliance can produce carbon
monoxide which has no odor.
• Using it in an enclosed space can kill you.
• Never use this appliance in an enclosed
space such as a camper, tent, car or home.
WARNING
FOR YOUR SAFETY:
For Outdoor Use Only (outside any enclosure)
Do Not Use For Cooking.
WARNING
FOR YOUR SAFETY:
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try lighting any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
• Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or gas supplier.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage.
Read the installation, operation, and maintenance
instructions thoroughly before installing or
servicing this equipment.
Save these instructions for future reference.
If you are assembling this unit for someone else,
give this manual to him or her to read and save
for future reference.
Made from 70% Bagasse
(Environmentally Friendly Sugar
Cane Pulp By-product)
LP Gas Outdoor Fire Bowl
Model No. GLT905W
CARBON MONOXIDE HAZARD

Table of Contents

Manufactured in China for:
Blue Rhino Global Sourcing, Inc.
Winston-Salem, NC USA
1.800.762.1142, www.bluerhino.com
© 2008 Blue Rhino Global Sourcing, Inc.. All Rights Reserved
OWNER'S MANUAL
Dangers and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2
Exploded View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Assembly Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing LP Gas Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Insert and Secure LP Gas Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Disconnect LP Gas Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operating Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Lighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Turning Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Inspecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Storing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
The use and installation of this product must conform to local codes. In absence of local codes,
use the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, CAN/CGA-B149.1,
Natural Gas and Propane Installation Code.
For installation in Canada - these instructions, while generally acceptable do not necessarily
comply with the Canadian installation codes, particularly with piping above and below ground.
In Canada the installation of this appliance must comply with local codes and/or standard
CAN/CGA B149.1 (installation code for propane burning appliances and equipment).
California Proposition 65: Chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm are created by the combustion of propane.
GLT905W-OM-109 ES

Advertisement

Table of Contents
loading

Summary of Contents for Blue Rhino WUSB-150

  • Page 1: Table Of Contents

    OWNER’S MANUAL LP Gas Outdoor Fire Bowl Model No. GLT905W DANGER CARBON MONOXIDE HAZARD • This appliance can produce carbon monoxide which has no odor. • Using it in an enclosed space can kill you. • Never use this appliance in an enclosed space such as a camper, tent, car or home.
  • Page 2: Dangers And Warnings

    LP Gas Outdoor Fire bowl Model No. GLT905W DANGERS and WARNINGS: FOR YOUR SAFETY DANGER: Failure to follow the dangers, warning and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion causing damage to property. WARNING: This appliance is for outdoor use only, and shall NOT be used in a building, garage, or Always use in accordance with all applicable local, state and national codes.
  • Page 3: Exploded View

    page no. Contact 1.800.762.1142 for assistance. Do not return to place of purchase. Parts List Exploded View Lava Rock 55-05-833 Pilot Cover* 55-05-834 Pilot* 55-05-835 Burner* 55-05-836 Bowl* 55-05-837 Body* 55-05-838 Valve Assembly* 55-05-839 Valve Bracket* 55-05-840 Control Knob* 55-05-841 Regulator* 55-05-842 Regulator Bracket*...
  • Page 4: Assembly Instructions

    LP Gas Outdoor Fire bowl Model No. GLT905W Assembly Instructions Installing LP Gas Tank To operate you will need (1) 16.4 oz LP gas tank. DO NOT RETURN PRODUCT TO STORE. For assistance call 1.800.762.1142 toll free. Please have your owner’s manual and serial number available for reference.
  • Page 5: Operating Instructions

    page no. Contact 1.800.762.1142 for assistance. Do not return to place of purchase. Operating Instructions Cleaning and Care Checking for Leaks Inspecting WARNING: Before using this outdoor fire bowl, make sure you have This outdoor fire bowl should be inspected on a regular basis to ensure product safety and read, understand and are following all information provided in the longer product life.
  • Page 6: Limited Warranty

    LP Gas Outdoor Fire bowl Model No. GLT905W Limited Warranty Blue Rhino Global Sourcing, Inc. (“Vendor”) warrants to the original retail purchaser of this product, and to no other person, that if this product is assembled and operated in accordance with the printed instructions accompanying it, then for a period of one (1) year from the date of purchase, all parts in such product shall be free from defects in material and workmanship.
  • Page 7: Troubleshooting

    page no. Contact 1.800.762.1142 for assistance. Do not return to place of purchase. Troubleshooting Problem Possible Cause Prevention/Cure Burner will not light using igniter Electrode and burners are wet. Wipe dry with cloth. Electrode cracked or broken - sparks at crack. Replace electrode.
  • Page 8 LP Gas Outdoor Fire bowl Model No. GLT905W...

This manual is also suitable for:

Wusb-150a v3Glt905w

Table of Contents