System Overview; Figure 1-4. Typical, Chain Switched, Redundant Diagram - Comtech EF Data MBT-4000 Installation And Operation Manual

Multi-band transceiver system
Hide thumbs Also See for MBT-4000:
Table of Contents

Advertisement

Multi-Band Transceiver System
Introduction
1.4 S
YSTEM
The transceiver is constructed in a modular configuration. Common to the configuration
for any frequency band of operation is a base module which provides the M&C, Power
Supply, and Reference function. Band-specific BUC and BDC modules can be mounted
to the base module with clip-type fasteners. BUC and BDC modules for other bands and
spares for all modules are stored in a transit case until needed.
ANTENNA HUB
1:1 LNA SUBSYSTEM
TX REJECT
FILTER
OMT
ANTENNA SYSTEM
RX REJECT
FILTER
O
VERVIEW
LNA 1
LNA 2
SWITCH 1 RF (J10)
SWITCH 2 RF (J10)
1:1 SSPA SUBSYSTEM
SSPA 1
SSPA 2

Figure 1-4. Typical, Chain Switched, Redundant Diagram

1:1 MBT SUBSYSTEM
AUX COM 1
(J9)
P/O COMMON MODULE 1
P/O COMMON MODULE 1
AUX COM 2
(J8)
REDUNDANCY
1:1 MBT SUBSYSTEM
AUX COM 1
(J9)
BDC 2
P/O COMMON MODULE 2
BUC 2
P/O COMMON MODULE 2
AUX COM 2 (J8)
CMAT
1-5
MN/MBT4000.IOM
BDC 1
BUC 1
CMAT
COMM (J2)
(J4)
SWITCH 1 IF
INTERLINK
CABLE
CMAT
COMM (J2)
Revision 3
L-BAND OUT
(J4)
SWITCH 2 IF
L-BAND IN

Advertisement

Table of Contents
loading

Table of Contents