NOTE TO INSTALLER:
THIS MANUAL MUST BE LEFT WITH THE
EQUIPMENT USER.
USER: PLEASE READ ALL INSTRUCTIONS
IN THE MANUAL AND RETAIN ALL
MANUALS FOR FUTURE REFERENCE.
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in injury, death, or
property damage.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
−Do not try to light any appliance.
−Do not touch any electrical switch; do not use any
phone in your building.
−Leave the building immediately.
−Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
−If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury
and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Install a
carbon monoxide alarm in your home, even if you do not
own a gas appliance. Locate the carbon monoxide alarm in
the living area of your home and away from gas appliances
and doorways to attached garages. Follow the alarm
manufacturer's instruction included with the alarm.
INDUCED COMBUSTION GAS FURNACE
Owner's Manual
Specifications subject to change without notice.
Illustrations and photographs are only representative.
Some product models may vary.
WARNING
!
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury,
death, or property damage.
Do not use this furnace if any part has been under water. A
flood−damaged furnace is extremely dangerous. Attempts to
use the furnace can result in fire or explosion. A qualified
service agency should be contacted to inspect the furnace and
to replace all gas controls, control system parts, electrical parts
that have been wet or the furnace if deemed necessary.
Use of the AHRI Certified TM Mark indicates a
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org .
441 02 7000 02 Dec. 2013

Advertisement

Table of Contents
loading

Summary of Contents for International comfort products 441 02 7000 02

  • Page 1: Combustible Materials, Gasoline Warning

    Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org . 441 02 7000 02 Dec. 2013 Specifications subject to change without notice.
  • Page 2: Table Of Contents

    This furnace contains safety devices which must be manually reset. If the furnace is left unattended for an extended period of time, 441 02 7000 02 Specifications subject to change without notice.
  • Page 3: Safety Considerations

    6. The burner flames are in good adjustment (by comparison with pictorial sketches or drawings of the main burner flame A08175 Fig. 3 − Lowest Temperature Setting and, if applicable, the pilot burner flame). 441 02 7000 02 Specifications subject to change without notice.
  • Page 4: Starting (Lighting) And Shutting Down The Furnace Warning

    If you do will energize. When hot, the igniter will have an orange glow. not smell gas, go to the next step. 441 02 7000 02 Specifications subject to change without notice.
  • Page 5: Shutting Down Your Furnace

    Turn off electrical power supply to your furnace before it with a new filter of same size. removing the access doors to service or perform maintenance. 441 02 7000 02 Specifications subject to change without notice.
  • Page 6: Combustion Area And Vent System

    OPERATE YOUR FURNACE. Call your dealer for service. NOTE: If your furnace makes a loud noise when the main burners are ignited, shut down the furnace and call your servicing dealer. 441 02 7000 02 Specifications subject to change without notice.
  • Page 7: Dirt, Rust, Or Accumulation Caution

    The switch will automatically reset after the furnace cools off. If the furnace fails to operate, contact a qualified Ask your servicing dealer for further details about an economical service agency. service contract that covers seasonal inspections. 441 02 7000 02 Specifications subject to change without notice.
  • Page 8: Before You Request A Service Call

    This list may not include all maintenance items, and inspection interval times may vary depending on operational conditions of the furnace. Ask your servicing dealer for further details about an economical service contract that covers seasonal inspections. Specifications subject to change without notice. Copyright 2013 International Comfort Products Lewisburg, TN 37091 USA...