Shutting The Projector Down; Resetting All Settings - Dukane 8917H User Manual

Liquid crystal projector
Hide thumbs Also See for 8917H:
Table of Contents

Advertisement

Troubleshooting
Regarding the indicator lamps (continued)
POWER
LAMP
indicator
indicator
Blinking
In
Red
Turned
or
off
Lighting
In
Red
Lighting
Simultaneous
In
Green
blinking in
Lighting
Alternative
In
Green
blinking in
NOTE
• When the interior portion has become overheated, for safety purposes,
the projector is automatically shut down, and the indicator lamps may also be
turned off. In such a case, disconnect the power cord, and wait at least 45 minutes.
After the projector has sufficiently cooled down, please make confirmation of the
attachment state of the lamp and lamp cover, and then turn the power on again.

Shutting the projector down

Only when the projector can not be turned off by usual
procedure (14) , please push the shutdown switch using
a pin or similar, and disconnect the power plug from the
power outlet. Before turning it on again, wait at least 10
minutes to make the projector cool down enough.

Resetting all settings

When it is hard to correct some wrong settings, the FACTORY RESET function of
SERVICE item in OPTION menu (45) can reset all settings(except LANGUAGE,
FILTER TIME, LAMP TIME, FILTER MESSAGE settings and etc.) to the factory
default.
62
TEMP
indicator
There is a possibility that the interior portion
has become heated.
Please turn the power off, and allow the projector to cool down at least
20 minutes. After the projector has sufficiently cooled down, please make
confirmation of the following items, and then turn the power on again.
Lighting
• Is there blockage of the air passage aperture?
In
Red
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the remedy, please set FAN
SPEED of SERVICE item in OPTION menu to HIGH
It is time to clean the air filter.
Please immediately turn the power off, and clean or change
the air filter referring to the section "Cleaning and replacing
Red
the air filter". After cleaning or changing the air filter, please
be sure to reset the filter timer.
After the remedy, reset the power to ON.
There is a possibility that the interior portion
has become overcooled.
Please use the unit within the usage temperature
Red
parameters (5°C to 35°C).
After the treatment, reset the power to ON.
Description
Shutdown switch
(44)
.

Advertisement

Table of Contents
loading

Table of Contents