CAUTION
Fireplace gas control must be in the "OFF" position and pilot
and main burners extinguished when cleaning appliance with
a vacuum.
Glass and logs can get very hot. Handle only when cool.
General
n
Have the fireplace installation inspected yearly, including a visual
check of the vent system, the burner and the pilot flame. For
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 25.
n
For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
n
For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.
n
Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours and
liquids.
n
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
Cleaning
When the fireplace is first activated, there may be some smoking and a
visible film may be left on the glass. This is a normal condition, and is
the result of burning the protective coatings on new metal.
n
Glass must be cleaned periodically to remove any film (a normal bi-
product of combustion) which may be visible. Film can easily be
removed by removing the door, as shown on page 13. Handle the
door carefully, and clean it with an approved glass cleaner. One of
the most effective products is Kel Kem.
n
Silicone seals on inner door during initial firing will "off gas", leaving
a visual deposit of a white substance on combustion chamber walls.
This can easily be removed by following the steps described below.
n
Use a vacuum cleaner or soft bristle brush to keep the control
compartment, burner, and firebox free from dust and lint.
n
Logs may be cleaned periodically with a vacuum to remove soot.
WARNING:
Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass
etching may cause premature glass failure.
P/N XG0205

Maintenance

Pilot Adjustment Screw
Inlet
Pressure
Figure 25. Sit Nova 820 gas valve.

Pilot Burner Adjustment

1. Locate Pilot Adjustment Screw. (See figure 25.)
2. Adjust pilot key to provide properly sized flame. (See figure 26).
3. After installing or servicing, leak test with a soap solution with main
burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.
Figure 26. Pilot Burner
M40DV-PFC Peninsula Gas Fireplace

Gas Control Valve

Manifold Pressure
Test Connection
Power
Generator
Wall Switch
Page 17