To Start The Engine; Stopping The Engine - Generac Power Systems Guardian Ultra Source 004451-1 Owner's Manual

Portable generator 12,500 watt guardian series
Table of Contents

Advertisement

Use regular UNLEADED gasoline with the generator engine. Do
not use premium gasoline. Do not mix oil with gasoline.
Clean area around fuel fill cap, remove cap.
Slowly add unleaded regular gasoline to fuel tank.
to overfill. Allow about 1/2" of tank space for fuel expansion,
as shown here.
Install fuel cap and wipe up any spilled gasoline.
Figure 14 - Fuel Tank
IMPORTANT: It is important to prevent gum deposits from forming
in fuel system parts such as the carburetor, fuel hose or tank
during storage. Alcohol-blended fuels (called gasohol, ethanol
or methanol) can attract moisture, which leads to separation and
formation of acids during storage. Acidic gas can damage the fuel
system of an engine while in storage. To avoid engine problems,
the fuel system should be emptied before storage of 30 days or
longer. See "Storage" on page 18. Never use engine or carburetor
cleaner products in the fuel tank as permanent damage may
occur.

2.7 TO START THE ENGINE

Never start or stop engine with electrical devices plugged
into the receptacles AND devices turned on.
Unplug all electrical loads from the unit's receptacles before
starting the engine.
ake sure the unit is in a level position.
Open the fuel shut-off valve.
Figure 15 - Fuel Shut-off Valve
Locate the Idle Control ON/OFF switch on the control panel and
set it to the "OFF" position.
Be careful not
Move engine CHOKE knob to "Full Choke" position.
To start engine, press and hold the Start/Run/Stop switch in
the "Start" position. The engine will crank and attempt to start.
When the engine starts, release the switch to the run position.
When the engine starts, move choke knob to "1/2 Choke"
position until the engine runs smoothly and then to "Run"
position. If engine falters, move choke knob to "1/2 Choke"
position until the engine runs smoothly and then to "Run"
position.
If engine fires, but does not continue to run, move choke lever
to "Full Choke" and repeat starting instructions.

2.8 STOPPING THE ENGINE

Shut off all loads, then unplug the electrical loads from generator
panel receptacles. Never start or stop the engine with electrical
devices plugged in and turned on.
Turn "Off" the Idle Control switch (if on).
Let engine run at no-load for several minutes to stabilize the
internal temperatures of engine and generator.
Move Start/Run/Stop switch to "Off" position.
Close fuel valve.
Section 2 – Operation
Portable Generator System
Figure 16 - Idle Control Switch
Figure 17 - Full Choke Position
NOTICE: