Safety Instructions
Connect Electricity . . . . . . . . . . . .3
Safety Precautions . . . . . . . . . . . . .2
Operating Instructions
Air Filter . . . . . . . . . . . . . . . . . . . . .7
Grille and Case . . . . . . . . . . . . . . . .7
Outdoor Coils . . . . . . . . . . . . . . . .7

Installation Instructions

Installation . . . . . . . . . . . . . . . . . .13
Window Installation . . . . . . . .9-12
Preparation . . . . . . . . . . . . . . . . . . .8
Consumer Support
Consumer Support . . .Back Cover
Warranty . . . . . . . . . . . . . . . . . . . .15
Write the model and serial
numbers here:
Model # ________________________
Serial # ________________________
Find these numbers on a label near
the air discharge area and/or on a label
on the side of the air conditioner.
. . . . . .5, 6
. . .8-13
. . . . . . .14
Owner's Manual and
Installation Instructions
AVX07
AVX08
AVX10
23-11-2111N-003
49-7413
01-01 JR

Advertisement

Table of Contents
loading

Summary of Contents for GE AVX07

  • Page 1: Table Of Contents

    Connect Electricity ... .3 Extension Cords ....4 AVX07 Safety Precautions ... . .2...
  • Page 2: Important Safety Information

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. SAFETY PRECAUTIONS Use this appliance only for its intended Turn the mode control to OFF and unplug...
  • Page 3: How To Connect Electricity

    www.GEAppliances.com HOW TO CONNECT ELECTRICITY Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded. The power cord of this appliance is equipped The air conditioner should always be with a 3-prong (grounding) plug which mates plugged into its own individual electrical with a standard 3-prong (grounding) wall...
  • Page 4: Use Of Adapter Plugs

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! USE OF EXTENSION CORDS – 115-Volt models only Because of potential safety hazards under CAUTION: certain conditions, we strongly recommend against the use of an extension cord. DO NOT use an extension cord with any of However, if you must use an extension cord, the 230/208 volt models.
  • Page 5: About The Controls On The Air Conditioner

    About the controls on the air conditioner. www.GEAppliances.com COOL COOL COOL MODE CONTROL TEMP CONTROL Controls Mode Control Temp Control HI COOL, MED COOL and LOW COOL provide The temp control is used to maintain the cooling with different fan speeds. room temperature.
  • Page 6 About the controls on the air conditioner. Additional controls and important information. Exhaust Control When set at CLOSED , only the air inside the room will be circulated and conditioned. When set at OPEN CLOSED OPEN , some inside air is exhausted outside. Air Direction The air direction tabs are located at the top on either side of the front grille.
  • Page 7: Care And Cleaning Of The Air Conditioner

    The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet. Air Filter The air filter behind the inlet grille should be checked and cleaned at least every 30 days or more often if necessary.
  • Page 8: Before You Begin

    Preparing to install the air conditioner. Read these instructions completely and carefully. Before You Begin NOTE TO INSTALLER: Leave these instructions CAUTION: with the air conditioner after installation is Do not, under any circumstances, cut or remove completed. the third (ground) prong from the power cord. NOTE TO CONSUMER: Keep this Owner’s Do not change the plug on the power cord of this Manual and Installation Instructions for future...
  • Page 9 Horizontal sliding window installation instructions. Read these instructions completely and carefully. Parts Included Foam window side gasket Adhesive back foam seal (3) Support platform Top retainer bar Sill plate Filler panel Support angle CLOSED OPEN COOL COOL MODE TEMP COOL Air conditioner Window stopping clips (2)
  • Page 10: Casement Window

    Horizontal sliding window installation instructions. Read completely, then follow step-by-step. Window Requirements These instructions are for a horizontal sliding For installation in a casement window, the or a casement window. window frame assembly and the side of the building must be adequate to support the The electrical outlet must be within reach of the weight of the air conditioner.
  • Page 11 Install the Air Conditioner in the Window Cut two pieces of adhesive back foam seal to Drill two 1/8″ holes in the window channel the height of the window opening. Remove frame through the existing holes in the the backing and apply to the vertical inside bottom bar.
  • Page 12 Horizontal sliding window installation instructions. Read completely, then follow step-by-step. Install the Filler Panel Trim the filler panel to fit the opening of the Drill 1/8″ holes to align with the existing height of the window. Attach the top retainer holes in the sliders.
  • Page 13 Casement window installation instructions. Read these instructions completely and carefully. Prepare the Window Decide where the air conditioner will fit best. If you want to install the air conditioner in a If you want to install the air conditioner in a window that opens you must remove the window that does not open, you need to catch handle and the entire crank handle...
  • Page 14: Troubleshooting Tips

    Before You Call For Service… Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service. Problem Possible Causes What To Do • Make sure the air conditioner plug is pushed completely Air conditioner The air conditioner into the outlet.
  • Page 15: Air Conditioner Warranty

    Any part of the air conditioner which fails due to a defect in materials or workmanship. One Year During this full one-year warranty, GE will also provide, free of charge, all labor From the date of the and in-home service to replace the defective part.
  • Page 16: Consumer Support

    Contact Us www.GEAppliances.com If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park...

This manual is also suitable for:

Avx08Avx10

Table of Contents