46
LED
State
PS
On (green)
Blinking (orange)
Blinking (orange)
LED Mode
Act (green)
Select
FDx (green)
PoE (green)
Spd (green)
Usr (green)
Table G-1: LED status indicators for management/system support module
The LED status indicators for the ProCurve 6600 switch ports are described in Table G-2 .
LED
State
Link
On (green)
Off
Blinking (orange)
Mode
Depending on the mode selected, displays:
• Network activity information
• Whether the port is configured for full duplex operation
• Maximum speed of operation
Table G-2: LED status indicators for ProCurve 6600 Switch Series Ethernet ports

Appendix H: links to other useful documents

White papers

Resources for Cisco interoperability, Data Center Connection Manager, Green IT initiatives, and so on, can be
found at
www.procurve.com/library/whitepapers.aspx

Technical briefs

Storage over Ethernet sources can be found at
www.procurve.com/docs/datacenter/Storage_Over_Ethernet_Technical_Brief_Dec_08_WW_Eng_Ltr.pdf
Documents related to HP ProCurve 6600 Switch Series and the data center
Sources about the 6600 series and the data center can be found at
www.procurve.com/library/view_by_product.aspx#Switch%206600
Indication
A power supply is installed in the position in the back of the switch, and the supply is plugged into an
active AC power source . As shipped, the switch has a single power supply in position 1 .
One of the switch's redundant power supplies has failed . The switch Fault LED will be blinking
simultaneously .
The external power supply has a fault or is connected but not plugged into AC power .
Flickers to show relative activity .
Flickers to show relative activity .
Indicates which ports are supplying power .
• I f the Mode LED is on, the port is providing PoE power.
• I f the Mode LED is off, the port is not providing PoE power.
• I f the Link LED is on, the port is enabled for PoE.
• I f the Link LED is off, the port is disabled for PoE.
• I f the Link LED is blinking, the port has an error or the port is denied power due to insufficient power.
Indicates speed of operation of each port .
• I f the Port LED is off, the port is operating at 10 Mbps.
• I f the Port LED is blinking, the port is operating at 100 Mbps.
• I f the Port LED is on continuously, the port is operating at 1000 Mbps.
Reserved for future development .
Indication
Indicates the port is enabled and receiving a link beat signal (for the twisted-pair ports), or a strong enough
light level (for the fiber-optic ports) from the connected device .
Indicates no active network cable is connected to the port, the port is not receiving link beat or sufficient
light, or the port has been disabled .
If the port LED is blinking simultaneously with the Fault LED, the corresponding port has failed its self-test .