3.8 Fiber Optical Port Specifications

Order
Speed
Mode /
Code
Standard
Connector
MJ
100FX
MM/MTRJ
MC
100FX
MM/SC
MT
100FX
MM/ST
ML
100FX
MM/LC
T2
100FX
SM/ST
L2
100FX
SM/LC
C2
100FX
SM/SC
L5
100FX
SM/LC
C5
100FX
SM/SC
L9
100FX
SM/LC
C9
100FX
SM/SC
Table 12 - Fiber Optic Port Specifications
NOTES:
1.
All values listed are average values
2.
To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
3.
Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and
splices. Please consult RuggedCom sales associates when determining maximum segment distances.
©
2008 RuggedCom Inc. All rights reserved
Tx
Cable
Tx
(nm)
Type
min
(um)
(dBm)
1300
50/125
-22.5
62.5/125
-19
1300
50/125
-22.5
62.5/125
-19
1300
50/125
-22.5
62.5/125
-19
1310
62.5/125
-19
1310
9/125
-15
1300
9/125
-15
1300
9/125
-15
1310
9/125
-5
1310
9/125
-5
1310
9/125
0
1310
9/125
5
18
Tx
Rx
Rx
max
Sensitivity
Saturation
(dBm)
(dBm)
(dBm)
-14
-33.5
-14
-14
-33.5
-14
-14
-33.9
-14
-14
-33.9
-14
-14
-33.9
-14
-14
-33.9
-14
-14
-32
-14
-7
-34
-3
-8
-38
-3
-8
-31
-7
0
-35
-3
0
-34
-3
5
-37
0
-37
Typical
Power
Distance
Budget
(km)
(dB)
2
11
2
14.5
2
11.4
2
14.9
2
11.4
2
14.9
2
13
20
19
20
23
20
16
50
30
50
29
0
90
37
0
90
42
Rev103