Honeywell VisionPRO IAQ Product Data page 14

Total home comfort system
Hide thumbs Also See for VisionPRO IAQ:
Table of Contents

Advertisement

®
VISIONPRO
IAQ TOTAL HOME COMFORT SYSTEM
ISU
Parameter
Installer Setup
Number
Name
200
Back-up Heat
Source Applies to
both Aux and
EmHeat
210
External Fossil
Fuel Kit
220
CPH for 1st
Stage Cool/
Compressor
230
CPH for 2nd
Stage Cool/
Compressor
240
CPH for 1st
Stage
Conventional
Heat or Auxiliary
250
CPH for 2nd
Stage
Conventional
Heat or 2nd
Stage Auxiliary
260
CPH for 3rd
Stage Heat
280
Continuous
USU
Backlight
300
Changeover
310
Deadband
320
Temperature
USU
Indication Scale
330
Daylight Saving
USU
340
Indoor Temp
Sensor
342
Outdoor Temp
Sensor
68-0287—1
Table 3. Installer Setup Menu. (Continued)
Settings
(Factory Defaults Shown in Bold)
0
Electric backup heat
1
Fossil fuel backup heat
E
Auto Discover
0
Thermostat controls backup heat
1
External Fossil Fuel kit controls backup heat
1-6
3—cph recommended for compressors
1, 2, 4, 5, 6—other cycle rate settings
E
Auto Discover
1-6
3—cph recommended for compressors
1, 2, 4, 5, 6—other cycle rate settings
E
Auto Discover
1-12
1—1 cph used for steam and gravity
3—3 cph used for hot water system and high
efficiency (90% or better) furnaces
5—5 cph used for standard fossil fuel forced air
(less than 80% efficient) systems
9—9 cph used for electric furnaces
2, 4, 6, 7, 8, 10, 11, 12—other cycle rate settings
E
Auto Discover
1-12
1—1 cph used for steam and gravity
3—3 cph for hot water systems and high efficiency
(90% or better) furnaces
5—5 cph for standard fossil fuel forced air (less
than 90% efficient) systems
9—9 cph used for electric furnaces or electric
auxiliary heat for heat pump systems
2, 4, 6, 7, 8, 10, 11, 12—other cycle rate settings
E
Auto Discover
1-12
1—1 cph used for steam and gravity
3—3 cph for hot water systems and high efficiency
(90% or better) furnaces
5—5 cph for standard fossil fuel forced air (less
than 90% efficient) systems
9—9 cph used for electric furnaces or electric
auxiliary heat for heat pump systems
2, 4, 6, 7, 8, 10, 11, 12—other cycle rate settings
E
Auto Discover
0
Backlight not on continuously. Thermostat
backlight comes on with each key press.
1
Backlight is on continuously.
0
Manual
1
Auto
2 1.5
2°F
1.5°C
3 2.0
3°F
2.0°C
4 2.5
4°F
2.5°C
5 3.0
5°F
3.0°C
6 3.5
6°F
3.5°C
7 4.0
7°F
4.0°C
8 4.5
8°F
4.5°C
9 5.0
9°F
5.0°C
Note: degrees C is not same as degrees F
0
Fahrenheit temperature display
1
Celsius temperature display
0
Disabled
1
Enabled (US 1987)
2
Enabled (US 2007)
0
Thermostat location only
1
Remote indoor sensor(s) location(s) only
2
Average between thermostat and sensor locations
0
None
1
Yes
E
Auto Discover
Only shown if ISU172 = 2 and ISU176 = 1 or greater.
Only shown if ISU172 = 2 and ISU200 = 1.
Only shown if ISU174 = 2.
Only shown if ISU172 = 2 and ISU176 = 1 or higher.
Default varies based on types of heating.
Only shown if ISU176 = 2 or for Heat Pump systems
with 2 stages of Auxiliary Heat.
Default varies based on types of heating.
Only shown if ISU176 = 3.
Default varies based on types of heating.
If backlight is on continuously, it is low-intensity. Light
changes to full brightness after pressing any key.
Auto Changeover allows user to choose heat, cool, off
or auto. When set to Auto the thermostat will
automatically choose heat or cool based on room
temperature and heat/cool set points. Manual
changeover allows the user to manually toggle
between heat, cool and off.
Only shown if ISU300 = 0. The deadband indicates the
minimum number of degrees that are allowed between
the heat and cool settings when in auto changeover.
For example, if the deadband is set to 3°F and the cool
setpoint is 75°F the warmest heat setpoint allowed
would be 72°F.
Set to 0 in areas that do not follow daylight savings
time.
Indoor temperature sensors will display the
temperature at the sensor location or an average of
two indoor temperature sensors, not including the
temperature sensor in the thermostat. The
temperature sensor in the thermostat is disabled when
using remote indoor temperature sensor(s).
An outdoor temperature sensor is required for heat
pump compressor lockout (ISU350), heat pump
auxiliary lockout (ISU360), dual fuel heat pump
balance point (ISU360) and Humidification with Frost
Protection (ISU372).
14
Notes