Download Print this page

Dryer Specifications - Hotpoint VWSR4150D Brochure & Specs

Hotpoint washer user manual

Advertisement

Electric
Dryers
Gas
Capacity
Capacity cu. ft
Controls
Rotary
Heat selections
Dry system
Temperature sensor
Dryer drum
Drum baffles
Signal
End-of-cycle
Dry cycles
Number of cycles
Cottons regular
Automatic dry cottons
Optional
Easy care
Automatic dry easy care
Wrinkle care
Timed dry
Maximum time available
Special cycles
Dewrinkle
Additional features
Quiet performance
Dryer interior light
Appearance
Colors Available*
Weights & dimensions
Approx. shipping weight - elect.
Approx. shipping weight - gas
H x W x D in inches
*WW = White on white, CC = Bisque on bisque.
**24-1/2" from the edge of the side panel to the front.
25-1/2" from front to edge of endcaps.
Dryer Exhausting Information—Use Metal Duct Only
Vertical and Horizontal Ducting
Maximum Length of 4"
A
Dia. Rigid Metal Duct
A
4
Number
of
B
90°
4" Opening
Turns
Domestic
2-1/2
Dryer Models
0
1
7.0 and 6.0
2
Capacity Models
3
all Electric Dryers
4
0
7.0 and 6.0
1
Capacity Models
2
all Gas Dryers
3
0
1
2
5.7 Capacity Electric
3
and Gas Dryers
4
NWSR483EB
NBXR463EB
NWSR483GB
NBXR463GB
7.0 Super
6.0 Extra-large
4
4
Thermostat
Thermostat
DuraDrum
DuraDrum
White
White
Variable
8
6
80 Mins.
80 Mins.
Quiet-by-Design
Quiet-by-Design
WW
WW
119
112
125
115
42 x 27 x 25-1/2**
42 x 27 x 25-1/2**
Best Performance
Maximum Length of 4"
Dia. Flexible Metal Duct
Exhaust Hood Type
Exhaust Hood Type
A
B
A
2-1/2"
4" Opening
Opening
90 ft.
60 ft.
55 ft.
60 ft.
45 ft.
40 ft.
45 ft.
35 ft.
30 ft.
35 ft.
25 ft.
20 ft.
25 ft.
15 ft.
15 ft.
90 ft.
60 ft.
55 ft.
60 ft.
45 ft.
40 ft.
45 ft.
35 ft.
30 ft.
35 ft.
25 ft.
20 ft.
60 ft.
48 ft.
30 ft.
52 ft.
40 ft.
22 ft.
44 ft.
32 ft.
14 ft.
32 ft.
24 ft.
28 ft.
16 ft.
NVL333EB
NVL333GB
5.7 Extra-large
3
Thermostat
DuraDrum
White
3
70 Mins.
Quiet-by-Design
WW/CC
125
130
42 x 27 x 25-1/2**
B
2-1/2"
Opening
45 ft.
30 ft.
20 ft.
15 ft.
10 ft.
45 ft.
30 ft.
20 ft.
15 ft.
18 ft.
14 ft.
10 ft.

Dryer Specifications

Dryer Exhausting Information
For complete information see installation instructions packed with dryer.
Important Note: GE Kit Number 14-A018 needed when converting
rear exhaust to bottom or side (on 5.7 extra-large capacity models only).
Ducting Materials
For best performance, this dryer should be vented with 4" diameter
all-rigid metal exhaust duct. If "all-rigid metal" duct cannot be used,
then "flexible all-metal" venting can be used, but it will reduce the
maximum recommended duct length.
The following kit or parts are available from your local service organization.
Kit WX8X75—7' aluminum duct and 4' hood, short tail.
(OR individual parts):
WX8X65 7' aluminum flex duct only
WX8X58 4' clamps (2)
WX8X67 4' exhaust hood
See installation instructions for complete information.
Exhaust length calculation:
1. Determine the number of 90° turns needed for your installation.
If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct
which can be tolerated is shown in the table. The maximum
lengths for flexible ducts are less than for rigid duct. See table
in installation instructions.
A turn of 45° or less may be ignored. Two 45° turns within the duct
length should be treated as a 90° elbow. A turn over 45° should be
treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to
prevent large amounts of moisture and lint from being blown into
the room. Gas dryers or any dryer located in a closet must be
exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney,
under any enclosed house floor (crawl space), or into an attic, since
the accumulated lint could create a fire hazard or moisture could cause
damage. Never terminate the exhaust into a common duct or plenum
with a kitchen exhaust, since the combination of lint and grease could
create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to
prevent back drafts, bird nesting, etc. The wall cap must also be
located at least 12" above the ground or any other obstruction with
the opening pointed down. Other terminations, such as louvered wall
boxes, are acceptable provided they are equivalent to a 4" opening
dampered wall cap.
Special Installation Requirements
Alcove or Closet Installation
• If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outdoors. See
installation instructions.
• Minimum clearances between dryer cabinet and adjacent
walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets,
ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and
must contain a minimum of 60 sq. in. of open area equally
distributed. If this closet contains both a washer and a dryer,
doors must contain a minimum of 120 sq. in. of open area
equally distributed.
• No other fuel-burning appliance shall be installed in the same
closet with a gas dryer.
Bathroom or Bedroom Installation
• The dryer MUST be exhausted to the outdoors.
See installation instructions.
• The installation must conform with the local codes, or in
the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.
Minimum Clearances other than Alcove or Closet Installations
• Minimum clearances to combustible surfaces:
0" both sides
3" rear
For more information on venting kits and accessories,
please call 1-800-GE-CARES.
Listed by
Underwriters
Laboratories
R
7

Advertisement

loading

This manual is also suitable for:

Vbsr3100dVvsr1070dVbxr1090d nwsr483ebNwsr483gbNbxr463ebNbxr463gb ... Show all