System Operation - Lennox Elite XC16−024−230 Installation Instructions Manual

Elite xc16 series
Table of Contents

Advertisement

°F
Psig
°F
Psig
32
100.8
48
137.1
33
102.9
49
139.6
34
105.0
50
142.2
35
107.1
51
144.8
36
109.2
52
147.4
37
111.4
53
150.1
38
113.6
54
152.8
39
115.8
55
155.5
40
118.0
56
158.2
41
120.3
57
161.0
42
122.6
58
163.9
43
125.0
59
166.7
44
127.3
60
169.6
45
129.7
61
172.6
46
132.2
62
175.4
47
134.6
Table 4. Normal Operating Pressures (Liquid +10 and Suction +5 psig)
IMPORTANT
Temp. of air
−024
entering
outdoor coil
5F (5C)
Liquid
65 (18.3)
215
75 (23.9)
247
85 (29.4)
288
95 (35.0)
332
105 (40.6)
381
115 (46.1)
435
65 (18.3)
225
75 (23.9)
258
85 (29.4)
301
95 (35.0)
346
105 (40.6)
397
115 (46.1)
452
*These are typical pressures only. Indoor indoor match up, indoor air quality, and indoor load will cause the pressures to vary.

System Operation

TWO−STAGE COMPRESSOR
The two−stage scroll compressor operates much like the
standard scroll compressor. The two−stage compressor
steps between low capacity and high capacity as required
to meet cooling demand. The steps occur when gas is
bypassed through a vent port in the first suction pocket.
This bypassing of gas allows the compressor to operate at
low capacity if thermostat demand allows, creating a more
cost effective and efficient compressor.
Table 3. HFC−410A Temperature (°F) − Pressure (Psig)
°F
Psig
°F
63
178.5
79
64
181.6
80
65
184.3
81
66
187.7
82
67
190.9
83
68
194.1
84
69
197.3
85
70
200.6
86
71
203.9
87
72
207.2
88
73
210.6
89
74
214.0
90
75
217.4
91
76
220.9
92
77
224.4
93
78
228.0
Use this table to perform maintenance checks; it is not a procedure for charging the
system. Minor variations in these pressures may be due to differences in installations.
Significant deviations could mean that the system is not properly charged or that a
problem exists with some component in the system.
−036
Suction
Liquid
First Stage (Low Capacity)
144
226
146
261
148
304
151
352
153
405
155
460
Second Stage (High Capacity)
140
228
142
262
144
306
146
353
149
405
151
462
Psig
°F
Psig
°F
231.6
94
290.8
110
235.3
95
295.1
111
239.0
96
299.4
112
242.7
97
303.8
113
246.5
98
308.2
114
250.3
99
312.7
115
254.1
100
317.2
116
258.0
101
321.8
117
262.0
102
326.4
118
266.0
103
331.0
119
270.0
104
335.7
120
274.1
105
340.5
121
278.2
106
345.3
122
282.3
107
350.1
123
286.5
108
355.0
124
109
360.0
−048
Suction
Liquid
142
224
144
258
145
299
147
345
150
395
150
450
144
235
146
269
148
313
150
361
151
412
154
471
Full capacity is achieved by blocking the vent port with a
slider ring. The slider ring (vent port cover) is controlled by
a 24VDC internal solenoid in the open position allowing low
capacity. When energized the internal solenoid closes the
slider ring, blocking the vent port and bringing the
compressor to full capacity. Stepping can occur during a
single thermostat demand as the motor runs continuously
while the compressor steps from low to full capacity.
Page 25
Psig
°F
Psig
365.0
125
445.9
141
370.0
126
451.8
142
375.1
127
457.6
143
380.2
128
463.5
144
385.4
129
469.5
145
390.7
130
475.6
146
396.0
131
481.6
147
401.3
132
487.8
148
406.7
133
494.0
149
412.2
134
500.2
150
417.7
135
506.5
151
423.2
136
512.9
152
428.8
137
519.3
153
434.5
138
525.8
154
440.2
139
532.4
155
140
539.0
−060
Suction
Liquid
142
215
144
250
146
291
148
337
150
388
153
444
135
220
137
256
139
299
141
347
143
402
146
462
°F
Psig
545.6
552.3
559.1
565.9
572.8
579.8
586.8
593.8
601.0
608.1
615.4
622.7
630.1
637.5
645.0
Suction
136
139
142
144
146
148
130
133
136
138
141
143
XC16 SERIES