Download Print this page

American Standard Yorkvilletm 3125.016 Specification Sheet

16-1/8" elongated pressure-assisted toilet

Advertisement

Quick Links

BARRIER FREE
YORKVILLE™ 16-1/8" ELONGATED
PRESSURE-ASSISTED TOILET
2325.101
• Vitreous china
• Low-consumption (6.0 Lpf/1.6 gpf)
• Floor-mounted, back-outlet toilet
• Elongated 16-1/8" high bowl
• Pressure-assisted siphon jet flush action
• Side-mounted chrome trip lever
• Close-coupled flushometer tank*
• Speed Connect
tank/bowl coupling system
®
• 4 bolt caps
• Fully glazed 2" ballpass trapway
• 10" x 12" water surface area
• 100% factory flush tested
3125.016 Elongated 16-1/8" high bowl with
four bolt caps and two floor screws
4099.100 Flushometer tank complete with
coupling components
Component parts:
735084-400 Tank cover (specify color)
Nominal Dimensions:
819 x 495 x 803mm
(32-1/4" x 19-1/2" x 31-5/8")
Alternate Configurations:
4099.700 Tank and tank cover only
with tank cover locking device
4099.800 Tank and tank cover only
with right hand trip lever
Fixture only, seat and supply by others
Recommended working pressure range 20 psi - 80ps
Compliance Certifications -
Meets or Exceeds the Following Specifications:
• ASME A112.19.2 for Vitreous China Fixtures
To Be Specified:
❏ Color: ❏ White ❏ Bone ❏ Linen
❏ Silver ❏ Fawn Beige
❏ Seat: American Standard #5324.019
Elongated "Rise and Shine" (with easy to clean
lift-off hinge system) solid plastic closed front
seat with cover.
❏ Seat: American Standard #5325.024
Elongated "Rise and Shine" (with easy to clean
lift-off hinge system) solid plastic open front
seat with cover.
❏ Alternate Seat:
❏ Supply with Stop:
* Flushmate III tank system by Flushmate
© 2008 AS America Inc.
❏ Black
®
Div. of Sloan Valve Co
YORKVILLE™ 16-1/8" ELONGATED
PRESSURE-ASSISTED TOILET
Replaces 2325.100
FINISHED WALL
819mm
(32-1/4)
19mm ± 6mm
(3/4 ± 1/4)
279mm
(11)
C/L OF SEAT
POST HOLES
140 mm (5-1/2)
CENTER
*
222mm
(8-3/4)
C/L OF 1/2" DIA HOLES
324mm
152mm (6) CENTERS
(12-3/4)
648mm
(25-1/2)
NOTES:
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-
FELT (WAX RING NOT RECOMMENDED).
SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED
SEPARATELY.
*
DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED.
FOR ADDITIONAL INFORMATION REFER TO INSTALLATION
INSTRUCTIONS SUPPLIED.
IMPORTANT: Dimensions of fixtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND
ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES-CHECK LOCAL CODES.
M42
VITREOUS CHINA
495mm
(19-1/2)
470mm
(18-1/2)
C/L
381mm
(15)
FLEX
SUPPLY
410mm
AS REQ.
(16-1/8)
102 mm
152 mm
(4)
(6)
76mm
(3)
C/L OF
WASTE
235mm
OUTLET
(9-1/4)
Revised 2/08
803mm
(31-5/8)
13 x 19mm
(1/2 x 3/4)
SLOTS
76mm
(3)
FINISHED
FLOOR

Advertisement

loading

This manual is also suitable for:

Yorkvilletm 4099.100Yorkvilletm 4099.700Yorkvilletm 4099.800Yorkvilletm 735084-400Yorkville 2325.101Yorkville 3125.016 ... Show all