Roland AR-3000 Reference Manual page 24

Rs-232c reference
Hide thumbs Also See for AR-3000:
Table of Contents

Advertisement

> PO (Phrase control Out set up for AR-3000)
Function: Control Out settings
Syntax:
stxPO: **** , *,**M**S;
a Phrase number
b Control Out
0 OFF
1 ON
c Offset Time (0M0S - 59M59S)
> PP (phrase Playback Point set up for AR-3000)
Function: Playback Point settings
Syntax:
stxPP: **** , **H**M**S**F*S, **H**M**S**F*S;
a Phrase number
b Start (0H0M0S0F0S - 23H59M59S**F9S)
c End (0H0M0S0F0S - 23H59M59S**F9S)
Note:
The number of digits for **F (frame) increases according to the value of MTC type.
> LP (phrase LooP set up for AR-3000)
Function: Loop Play settings
Syntax:
stxLP: **** ,*,*, **H**M**S**F*S, **H**M**S**F*S;
a Phrase number
b Loop Play
0 OFF
1 ON
c The number of loops
0 ENDLESS
1
1
|
99 99
d Loop 1 position (0H0M0S0F0S - 23H59M59S**F9S)
e Loop 2 position (0H0M0S0F0S - 23H59M59S**F9S)
Note:
The number of digits for **F (frame) increases according to the value of MTC type.
> PY (Phrase delaY set up for AR-3000)
Function: Delay Time settings
Syntax:
stxPY: **** , **S**F;
a Phrase number
b Delay Time (0S0F - 59S**F)
Note:
The number of digits for **F (frame) increases according to the value of MTC type.
a
b
c
a
b
a
b c
d
a
b
c
e
AR-3000 RS-232C Reference
r
-
19

Advertisement

Table of Contents
loading

Table of Contents