Layout Diagram; Radio Alignment - Philips AZ 5130 Service Manual

Vcd mp3 cd soundmachine
Hide thumbs Also See for AZ 5130:
Table of Contents

Advertisement

TUNER AND POWER AMPLIFIER BOARD - LAYOUT DIAGRAM
7 - 2
7 - 2
Alignment Procedure
Model No. AZ-5130
Instruments Required :
1.
AM Signal Generator
2.
FM Signal Generator
3.
AM/FM if Sweep Generator
4.
Dual Trace Oscilloscope
5.
Solid State Voltage Meter (SSVM)
6.
Frequency Counter
7.
Nonmetallic Alignment Tools
8.
Test Tape : Teac - MTT ñ 113N (6.3 kHz) or Equiv.
9.
Test Tape : Teac - MTT ñ 111N (3 kHz) or Equiv.
Important
1.
Check Power Source Voltage
2.
Set the Function Switch to Band Being Aligned.
3.
Volume Should Be Turned To Minimum.
4.
Signal Input Should be Kept as Low as Possible.
5.
AM Modulation : 1 kHz 30%
6.
FM Modulation : 1 kHz 22.5 kHz DEV.

Radio Alignment

Frequency
Input
Varian
MW IF
LOOP
455 kHz
ANT
MIN.
AM Coil
MW IF
520 kHz
MAX.
LOOP
1750 kHz
MIN.
ANT
600 kHz
600 kHz
AM Coil
1400 kHz
1400 kHz
FM IF
IC301
10.7 MHz
MIN.
Pins 4
FM IF
87.5 MHz
MAX.
FM ANT.
108.5 MHz
MIN.
C312
90 MHz
90 MHz
Cer. Cap.
106 MHz
106 MHz
Adjust
Output
Scope/Meter
IC301
T302
MAX.
Pins 18
T301
MAX.
VC301C
IC301
Pins 18
L305
MAX.
VC301D
IC301
Symmetrical
T303
Pins 18
L302
MAX.
VC301A
IC301
Pins 18
L303
MAX.
VC301B

Advertisement

Table of Contents
loading