Sanyo PLC-SU70 Service Manual page 32

Hide thumbs Also See for PLC-SU70:
Table of Contents

Advertisement

Electrical Adjustments
Item No.
NAME
2
DIMMER_CTRL_LEVEL3
3
DIMMER_CTRL_LEVEL4
4
DIMMER_CTRL_LEVEL5
5
DIMMER_CTRL_LEVEL6
6
DIMMER_CTRL_LEVEL7
7
DIMMER_CTRL_LEVEL8
8
DIMMER_CTRL_LEVEL9
9
DIMMER_CTRL_LEVEL10
10
DIMMER_CTRL_LEVEL11
11
DIMMER_CTRL_LEVEL12
12
DIMMER_CTRL_LEVEL13
13
DIMMER_CTRL_LEVEL14
14
DIMMER_CTRL_LEVEL15
15
DIMMER_AVERAGE_POINT
16
DIMMER_AVERAGE_DATA
17
DIMMER_LEVEL_AUTO
18
DIMMER_LEVEL_NORMAL
19
DIMMER_LEVEL_ECO
20
Lamp check enable
21
VOLTAGE_LEVEL
Group 111
FAN CONTROL
0
FAN_TEMP_A_WARNING
1
FAN_TEMP_B_WARNING
2
FAN_TEMP_C_WARNING
3
FAN_TEMP_B-A_WARNING
4
FAN_TEMP_C-A_WARNING
5
FAN_1_SPEED_MONI
6
FAN_2_SPEED_MONI
7
FAN_TEMP_A_MONI
8
FAN_TEMP_B_MONI
9
FAN_TEMP_C_MONI
10
Lamp Mode
11
Fan Ctrl Mode
12
FAN_CONTROL_SW
13
Hi-Land SW
14
Safety FAN Control Fix SW
15
FAN_1_SPEED_CTRL
16
FAN_2_SPEED_CTRL
TEMP_UPWARNING_TIME_A
17
(OUTSIDE)
TEMP_UPWARNING_TIME_B
18
(PANEL)
TEMP_UPWARNING_TIME_C
19
(LAMP)
20
TEMP_UPWARNING_TIME_B-A
21
TEMP_UPWARNING_TIME_C-A
22
UPWARNING_TEMP_A (OUTSIDE) PW185B
23
UPWARNING_TEMP_B (PANEL)
24
UPWARNING_TEMP_C (LAMP)
25
UPWARNING_TEMP_B-A
26
UPWARNING_TEMP_C-A
27
FAN_1_START_SPEED
28
FAN_2_START_SPEED
FAN_1_START_SPEED_CHANGE_
29
RATE
FAN_2_START_SPEED_CHANGE_
30
RATE
31
FAN_1_COOLING_SPEED
32
FAN_2_COOLING_SPEED
33
FAN_1_TEMPERROR_SPEED
34
FAN_2_TEMPERROR_SPEED
35
Cooling Time L1
36
Cooling Time L2
37
IGNORE_TEMP_CHANGE_RATE
38
IGNORE_TEMP_CHANGE_TIMES PW185B
39
40
41
42
NOR_TEMP_FAN1_MIN
43
NOR_TEMP_FAN1_MAX
44
NOR_TEMP_FAN2_MIN
45
NOR_TEMP_FAN2_MAX
SVGA
Device
Component
PC
HDTV
480p
PW185B
53
PW185B
70
PW185B
88
PW185B
105
PW185B
255
PW185B
255
PW185B
255
PW185B
255
PW185B
255
PW185B
255
PW185B
255
PW185B
255
PW185B
255
PW185B
4
PW185B
-
PW185B
-
PW185B
6
PW185B
0
PW185B
1
PW185B
-
Normal
Ceiling
Normal/Ceiling Ceiling/Hi-land
PW185B
49
55
PW185B
63
68
PW185B
67
65
PW185B
100
100
PW185B
100
100
PW185B
-
PW185B
-
PW185B
-
PW185B
-
PW185B
-
PW185B
Auto
PW185B
Normal
PW185B
0
M62398FP
0
M62398FP
0
PW185B
135
PW185B
135
PW185B
3
PW185B
3
PW185B
3
PW185B
3
PW185B
3
8
PW185B
5
PW185B
8
PW185B
8
PW185B
8
PW185B
80
PW185B
80
PW185B
2
PW185B
2
PW185B
100
PW185B
100
PW185B
135
PW185B
135
M62398FP
3
M62398FP
4
PW185B
10
5
PW185B
41
PW185B
45
PW185B
41
PW185B
45
Range Description
Video
480i
NTSC
PAL
Luminance Level3:Dimmer Level3 when less than the value.
Luminance Level4:Dimmer Level4 when less than the value.
Luminance Level5:Dimmer Level5 when less than the value.
Luminance Level6:Dimmer Level6 when less than the value.
Luminance Level7:Dimmer Level7 when less than the value.
Luminance Level8:Dimmer Level8 when less than the value.
Luminance Level9:Dimmer Level9 when less than the value.
Luminance Level10:Dimmer Level10 when less than the value.
Luminance Level11:Dimmer Level11 when less than the value.
Luminance Level12:Dimmer Level12 when less than the value.
Luminance Level13:Dimmer Level13 when less than the value.(Not used for
PH)
Luminance Level14:Dimmer Level14 when less than the value.(Not used for
PH)
Luminance Level15:Dimmer Level15 when less than the value.(Not used for
PH)
Avarage point of Luminance data for Dimmer
Avarage value of Luminance data for Dimmer, Read only
Present Dimmer Lavel
Dimmer Level at Normal
Dimmer Level at Eco
1: Lamp Fail Detection On (White 50% back), 0: Off (Blue 100% back)
Lamp Voltage, Read only 8bit value
43
48
30-100 Temp A to judge temperature Error (Memorized)for Outside temp.
54
62
30-100 Temp B to judge temperature Error (Memorized)for Panel temp.
61
67
30-100 Temp C to judge temperature Error (Memorized)for Lamp temp.
100
100
0-100
Temp B-A to judge temperature Error (Memorized)for Filter cloggle detection
100
100
0-100
Temp C-A to judge temperature Error (Memorized)for Filter cloggle detection
0-255
Fan Speed Monitor (Read only)
0-255
Fan Speed Monitor (Read only)
-
-
0-2
Normal/Auto/Eco
0-1
Normal/Ceiling Switching
0:Auto, 1:Max, 2:Min, 3:Manual
0-3
Auto/Max/Min/ManualSwitching
0: Normal mode 1:Highland mode
0-5
2~4: Highland mode 1~3 5:Fixed
For Safety Test FAN Control
0:Normal, 1:Normal Min, 2:Normal Max, 3:Eco Min, 4:Eco Max (Not Memo-
rized),1-4 Temp Error at 100ºC
0-255
Manual Adj. mode at FAN_CONTROL_SW=3 Normal
0-255
Manual Adj. mode at FAN_CONTROL_SW=3 Normal
0-5
Setup Error Temp. for a duration of X minites started from Power ON
0-5
Setup Error Temp. for a duration of X minites started from Power ON
0-5
Setup Error Temp. for a duration of X minites started from Power ON
0-5
Setup Error Temp. for a duration of X minites started from Power ON
0-5
Setup Error Temp. for a duration of X minites started from Power ON
Increase XºC for Error Temp. for a limitted time started from Power ON
Increase XºC for Error Temp. for a limitted time started from Power ON
Increase XºC for Error Temp. for a limitted time started from Power ON
Increase XºC for Error Temp. for a limitted time started from Power ON
Increase XºC for Error Temp. for a limitted time started from Power ON
0-255
Start Volotage 8V Fan sereis 1
0-255
Start Volotage 8V Fan sereis 1
?
Variation per 1 sec. for Fan series 1 0.1V/Sec
?
Variation per 1 sec. for Fan series 2 0.1V/Sec
0-255
Fan series 1 Voltage at PowerOFF(Fan ModeL1)
0-255
Fan series 2 Voltage at PowerOFF(Fan ModeL1)
0-255
Fan series 1 Voltage at Temp Error
0-255
Fan series 2 Voltage at Temp Error
1-15
Cooling time setting for Fan Mode L1 (x30sec)1:30sec3:90sec15:450sec
1-15
Cooling time setting for Fan Mode L2 (x30sec)1:30sec3:90sec15:450sec
5-50
Margin setting
1-9
Margin setting
FAN1 Control start temp.at Normal
FAN1 Control end temp. at Normal
0-255
FAN2 Control start temp.at Normal
FAN2 Control end temp. at Normal
-32-

Advertisement

Table of Contents
loading

Table of Contents