Specifications - Kenmore 795.78542.801 Service Manual

Table of Contents

Advertisement

1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE
SERVICING
IMPORTANT – RECONNECT ALL
GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts, or washers used to complete a path to ground
are removed for service, they must be returned to their
original positions, and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals,
possessing adequate backgrounds of electrical, electronic,
and mechanical experience. Any attempt to repair a major
appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (Freezer Compartment)...-6°F to +8°F
Defrost Control...Total Comp Running Time : 7 hrs ~ 50 hrs
Defrost Thermostat .......................................................46°F
Electrical Rating : 115VAC, 60Hz.................................1-5 A
Maximum Current Leakage.......................................0.5 mA
Maximum Ground Path Resistance ....................0.14 Ohms
Energy Consumption .....21 cu.ft. 457 kWh/yr (Energy Star)
.......................................25 cu.ft. 476 kWh/yr (Energy Star)
1-4 NO LOAD PERFORMANCE
CONTROL POSITION: MID/MID
Ambient of:..........................70°F..................................90°F
Fresh Food, °F ....................33°F to 41°F.........33°F to 41°F
Frozen Food, °F ..................-4°F to +4°F ..........-4°F to +4°F
Percent Running Time ........35%-45% .................50°F-70°F
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ............... 20 MIN.
Minimum Equalized Pressure
@ 70°F ....................................................... 52 PSIG
@ 90°F ....................................................... 59 PSIG
Refrigerant R134a ................................................. 4.59 oz.
Compressor ..................................................... 821 BTU/hr
1-6 INSTALLATION
Clearance must be provided at top, sides, and rear of the
refrigerator for air circulation.
AT TOP ......................................................................... 2 in
AT SIDES ...................................................................... 1 in
AT REAR ...................................................................... 1 in
1-7 REPLACEMENT PARTS
Relay
Overload
Defrost Thermostat
Defrost Heater
Evaporator Fan Motor
Capacitor (Running)
Compressor (Hi-Side)
Evaporator (Lo-Side)
Condenser
Dryer
Condenser Fan Motor
Temperature Control
Main Control
1-8 AIR FLOW / CIRCULATION D'AIR
EVAPORTOR FAN MOTOR
- 3 -
25 cuft
795. 78542.801 795. 78552.801
795. 78543.801 795. 78553.801
795. 78544.801 795. 78554.801
795. 78546.801 795. 78556.801
795. 78549.801 795. 78559.801
EBG44308701
EBG44308701
6615JB2005H
5300JK1005D
4681JK1004D
0CZZJB2014G
2521JA1006L
5421JJ1003B
ACG36653801
5851JA2008U
4681JB1029D
6871JB1439B
6871JB1423H
CONDENSER FAN MOTOR