Honeywell Trol-A-Temp T8090T Owner's Manual page 13

Zone thermostat heating/cooling thermostat and subbase or wallplate
Table of Contents

Advertisement

Setting the Heating Program
Decide when you want the temperature to reach the comfort level. Find the notch on the dial
that is one-half hour before this time and insert a
furnace time to heat the house before you wake up or arrive home.
Decide when you want the energy
saving period to start and insert a
blue
pin at the notch that corre-
sponds to this time. After the blue
pin engages, the furnace will be off
until room temperature drops to the
energy saving setpoint.
You can set both a day and a night
program. See Fig. 5 for program
examples.
red
pin. The half-hour head start gives the
TEMPERATURE
°F
58
BEGINS
NIGHT
10:00 PM
ENERGY
SAVING
ENDS
68
PERIOD
6:00 AM
DAY
BEGINS
58
ENERGY
7:30 AM
SAVING
ENDS
68
PERIOD
4:00 PM
Fig. 5—Programming examples.
13
WINTER
PROGRAM
TEMPERATURE
PIN IN
CONTROL
°C
°F
14
BLUE
80
20
RED
75
14
BLUE
80
20
RED
75
SUMMER
PROGRAM
PIN IN
°C
CONTROL
27
RED
24
BLUE
27
RED
24
BLUE
M626A