WIRING

The sensor can be used to provide one remote sensor (see Fig. 6) or as a temperature averaging network with multiple
sensors connected (see Fig. 7). The thermostat is not part of the average network.
CAUTION
ELECTRICAL HAZARD.
Can cause electrical shock or equipment damage. Disconnect power before wiring.
1. Run the wire cable from the thermostat to the
remote sensor location.
2. Loosen screw terminals, insert wires into terminal
block (polarity does not matter), then retighten
screws.
3. Push excess wire back into the wall opening.
4. Plug the wall opening with non-flammable insulation
to prevent drafts from affecting the sensor operation
and replace the cover on the remote sensor.
5. Connect the two wires to the thermostat's remote
sensor terminals (polarity does not matter) and
replace the thermostat back onto the wallplate. See
Fig. 6.
Y2
W2
S1
S2
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
1
OVERLOAD PROTECTION AS REQUIRED.
IF MORE THAN ONE C7189 REMOTE SENSOR IS REQUIRED,
2
REFER TO FIGURE 7.
WIRES MUST HAVE A CABLE SEPARATE FROM THE
3
THERMOSTAT CABLE.
Fig. 6. Wiring a single C7189U Sensor.

OPERATION

Once a remote indoor temperature sensor is connected to
the thermostat, the thermostat's sensor is no longer used.
The thermostat's installer setup should be modified to tell
the thermostat that remote indoor temperature sensor(s)
have been used. The Inside temperature reading on the
thermostat's display will be the remote sensor(s)
temperature location(s). See Fig. 8.
C7189
2
3
RC
R
W
Y
G
C
1
R
C
M19972A
SENSORS MUST BE ARRANGED IN THIS
1
CONFIGURATION TO OPERATE CORRECTLY.
WIRES MUST HAVE A CABLE SEPARATE FROM THE
2
THERMOSTAT CABLE.
Fig. 7. Wiring Multiple C7189U Sensors.
.
Fig. 8. Inside Temperature Reading on TH8000 Series
3
C7189U REMOTE INDOOR SENSOR
M24116
Fig. 5. Terminal block wiring.
Y2
W2
1
2
1
C7189
C7189
S2
C7189
C7189
Y2
W2
2
1
C7189
C7189
2
C7189
C7189
C7189
C7189
TUE
CHANGE FILTER UV LAMP HUMIDIFIER PAD
FAN
Inside
Set To
AUTO
Heat On
Following
SYSTEM
Schedule
HEAT
AM
SCHED
HOLD
CLOCK SCREEN
MORE
Thermostat.
1
C7189
C7189
C7189
M19973
M19974
69-1710EFS-1

Advertisement

Table of Contents
loading

Table of Contents