FlashGuard 2000B Troubleshooting Guide

Flashhead Isolation Test

Disconnect the seven conductor cable from power supply at terminal block TB2. Using
an Ohmmeter, check the resistance between the conductors of the disconnected
flashhead cable, and compare to the expected values:
FG 2000B White Strobe (cable disconnected from power supply)
#1 Red: Open to all conductors
#2 Brown: Open to all conductors
#3 Black: < 5
#4 Blue: < 5
#5 White: < 5
#6 Gray: < 5
#7 Ground: Open to all conductors
Flashhead Test Results
1. Correct readings do not ensure that the flashhead and cable are good, but this is a
quick check for obvious problems.
2. If the readings above are correct, proceed to the Power Supply Isolation Test.
3. If #5 (gray) to #6 (white) is greater than 5 , or is 'open', suspect that the flashhead
interlock switch is not depressed.
4. For other inconsistencies with the above chart, the probable causes are miswiring, or
conductors shorted and/or opened. If possible, disconnect the flashhead cable at
both ends and perform a 'Megger' test with a Megohm Meter.
to blue, open to all others
to black, open to all others
to gray, open to all others
to white, open to all others