  • Page 1 OWNER’S GUIDE F52F ELECTRONIC AIR CLEANER Copyright © 1998 Honeywell Inc. 69-0419—2 All Rights Reserved 69-0419-2...
  • Page 2 69-0419—2...
  • Page 3: Table Of Contents

    OPERATING YOUR ELECTRONIC AIR CLEANER GETTING THE MOST FROM YOUR AIR CLEANER CLEANING THE CELL(S) AND PREFILTER HOW ELECTRONIC AIR CLEANING WORKS BEFORE YOU CALL FOR SERVICE HONEYWELL 10 YEAR CLEAN COIL GUARANTEE PERFECT CLIMATE® LIMITED TWO-YEAR WARRANTY PAGE 69-0419—2...
  • Page 4: The Solid State Performance Indicator

    ON LED is lit (whenever the system fan is on). • If excessive dirt has accumulated on the air cleaner’s cell(s), the WASH LED will light to alert you that a cell and prefilter wash is past due.
  • Page 5: Operating Your Electronic Air Cleaner

    When the fan comes on, the neon light located near the ON-OFF switch will light, indicating that the air cleaner is functioning. ONE-CELL MODEL SHOWN. If your air cleaner is equipped with a wall-mounted W8600E Solid State Performance Indicator (see page 2), WASH CHECK the ON LED will be on whenever the air cleaner is in operation .
  • Page 6 When the fan stops, the neon light goes out, as does the ON LED on the ONE-CELL MODEL SHOWN. Solid State Performance Indicator. The air cleaner is off until the heating or air conditioning and fan start again. WASH CHECK...
  • Page 7: Getting The Most From Your Air Cleaner

    To do this, set the fan switch on your thermostat to ON, and make sure the air cleaner is switched on. The fan and air cleaner will run even when the furnace or air conditioner is off. Note: A manual fan switch may be built into the furnace fan controller.
  • Page 8: Cleaning The Cell(S) And Prefilter

    If your air cleaner has a W8600E Indicator (shown on page 2), the WASH LED will light to remind you that a cell and prefilter washing is past due. When the WASH LED comes on, it means that the cell(s) are loaded with dirt to the point that air cleaning efficiency is diminished.
  • Page 9 Removing the electronic cell(s) and prefilter STEP 1 Open the door by turning the two door latches. STEP 2 The prefilter is held in place by a spring clip and a U-shaped channel. Lift the prefilter at the spring clip end and slide it out of the U-shaped channel.
  • Page 10 69-0419—2 CELL LATCH STEP 3 The electronic cell(s) are held in the air cleaner by a latch at the top, and metal hooks on the bottom. Push the cell inward to release the latch and rotate the latch away from the cell. See photo.
  • Page 11 • Do not allow the dishwasher to run through the dry cycle. This bakes on any contaminants not removed during the wash cycle and reduces air cleaner efficiency. STEP 1 Put the cell(s) on the lower rack of the dishwasher with the airflow arrow pointing up.
  • Page 12 Washing the cell(s) in a tub 69-0419—2 CAUTION Hazardous chemical. Can cause personal injury. • Do not splash the detergent solution in eyes. Wear rubber gloves to avoid prolonged de- tergent contact with skin. • Keep detergent and solution out of reach of children.
  • Page 13 STEP 1 Inspect the cell(s) for broken ionizer wires and bent collector plates. Repair as necessary or take to a Honeywell authorized air cleaner repair station. 69-0419—2...
  • Page 14 Airflow arrows on the cell(s) must point into the air duct. c. Hook the cell(s) on the metal hooks and rotate into the air cleaner. d. Rotate the cell latch to secure the cell(s). CELL LATCH M9676A...
  • Page 15 STEP 3 Slide the prefilter into the U-shaped channel and push the other end past the spring clip. PREFILTER SCREEN SPRING CLIP INSERT TOP OF SCREEN INTO U-SHAPED CHANNEL M7813 69-0419—2...
  • Page 16 If the arcing is annoying, simply turn off the air cleaner for 2 to 3 hours or until the cell(s) are dry. If your air cleaner has a Solid State Performance Indicator, the CHECK LED may come on if you install wet cell(s) and prefilter.
  • Page 17: How Electronic Air Cleaning Works

    Generally, particles smaller than ten microns can be seen only with a microscope, except in very large concentrations such as a puff of smoke. Your electronic air cleaner can remove even smaller particles that can be seen only with an electron microscope.
  • Page 18 These particles are generated by normal household activities, and also enter the house from outside. That is why we recommend that you use the air cleaner as much as possible. CELL COLLECTOR PLATES...
  • Page 19 The regular furnace filter collects mainly large, visible particles that reach the filter. Its main purpose is to protect the furnace and air conditioner blower. The electronic air cleaner collects these large particles, plus many of the smaller, mostly invisible particles. Its purpose is...
  • Page 20 By comparison, an electronic air cleaner deposits contamination on the cell(s) and prefilter for easy cleaning. Another benefit of an electronic air cleaner is that it reduces excessive positive or negative ions in the air, while an air ionizer generates some ions.
  • Page 21 “white dust” If desired, the ozone generated by the air cleaner can be reduced by asking your dealer to adjust the air cleaner power supply to reduce ozone production. This adjustment will reduce ozone production about 20 to 25 percent, but will also reduce air cleaning efficiency about 7 to 10 percent.
  • Page 22: Before You Call For Service

    If the door is not closed, an interlock keeps the air cleaner OFF. 5. Check the neon light; if on, air cleaner is operating properly; if off, call for service. 1. If the electronic cell(s) are wet from washing, turn off the air cleaner for 2 to 3 hours.
  • Page 23 The neon light on the air cleaner doesn’t come on The WASH LED on the W8600E comes on The CHECK LED on the W8600E comes on You smell ozone and find it objectionable 1. Make sure the furnace or air conditioner blower is running.
  • Page 24: Honeywell 10 Year Clean Coil Guarantee

    Honeywell Electronic Air Cleaner. If your coil requires cleaning within the next ten years, Honeywell will pay 50 percent of the cost to have the coil professionally cleaned by a qualified heating/cooling contractor, or $100, whichever is less.
  • Page 25 , send copies of invoices verifying: • Purchase of a new Honeywell Electronic Air Cleaner. • Purchase of a heat pump, air conditioner or high efficiency furnace that is new or less than one year old.
  • Page 26: Perfect Climate

    If you have a standing pilot heating system less than 7 to 10 years old, you can stay comfortable and save even more. Team your new air cleaner and thermostat with Honeywell Electronic Ignition and an Automatic Vent Damper and save a total of up to 36% on energy costs for your gas furnace or boiler.
  • Page 27: Limited Two-Year Warranty

    Plymouth, MN 55441-4437 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
  • Page 28 Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis, MN 55408-0524 69-0419—2 69-0419—2 L.C. Rev. 2-98 Printed in U.S.A. on recycled paper containing at least 10% www.honeywell.com post-consumer paper fibers.

Table of Contents