Samsung SCP-3430H User Manual page 46

Smart dome camera
Hide thumbs Also See for SCP-3430H:
Table of Contents

Advertisement

setup
M
_ setup
er Manual_SCC-C7455P_ENGLISH-146 46
ALARM IN SET : Select the alarm sensor
operation between <NO>, <NC> and
<OFF>.
ALARM OUT SET : Set the alarm out
port matched to the alarm input port.
AUTO SET : Sets the pattern and scan
action for the corresponding alarm
input. When the alarm is generated, the
camera moves to the preset position
coupled to the corresponding alarm.
Presets 1 ~ 8 are coupled with alarms
1 ~ 8 inputs respectively, and the preset 9 is coupled to the motion
detection.
The camera stops and remains in the corresponding preset position for the
defined <DWELL TImE>, and performs pattern or scan action defined by
the <AUTO SET>. Setting to <OFF> will discard with the pattern or scan
action after moving to the preset position.
- PATTERN 1 ~ 3 : Defined pattern action
- HALF1 : Patterns 1 and 2 in serial action
- HALF2 : Patterns 2 and 3 in serial action
- WHOLE : Patterns 1, 2 and 3 in serial action
- SCAN 1 ~ 4 : Predefined SCAN action
The <ALARM1> is used as external switching signal if the <DAY/NIGHT> is set to
<EXT>.
AUX OUT CONTROL : Sets whether to
sustain the alarm output despite of the
alarm generation or to output alarm out
signal while the coupled alarm is alive.
When selected <OFF>, outputs alarm
only if the alarm is generated. When
selected <ON>, it always outputs
alarm out signal despite of the alarm
generation.
AUTO SET
ALARM1
ALARM2
ALARM3
ALARM4
ALARM5
ALARM6
ALARM7
ALARM8
MOTION
AUX OUT CONTROL
OUT1
OUT2
OUT3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2010-5-30 16:14:4