Installation
How to Fix Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
Installation Plate
Type "A" screw
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for pip-
ing connections must be done safely.
C
Installation plate
Ø70mm
Left rear piping
CHASSIS
(Grade)
A
S6(9k)
75
SR2(12k)
0
ST2(18k/24k)
105
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
A
Ø70mm
Right rear piping
Distance (mm)
B
C
D
12
80
12
40
20
40
0
210
0
Drill a Hole in the Wall
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
Indoor
• Open the Front Grille.
• Pass Telephone Control Cord Wire through the hole
which the power cord goes through.
• Connect Telephone Control Cord Wire to the phone jack
of telephone PCB of Control Box.
• Fix Telephone Control Cord Wire inside Control box so
as not to disconnect.
• Close the Front Grille.
Drain hose junction
• Remove the rubber stopple in the desired drain direc-
tion.
• Insert drain hose into the handle of drain pan, and join
drain hose and connecting hose according to the figure
by.
Only the
desired direction
- 16 -
WALL
Outdoor
Adhesive
Connecting
part
Drain