Chapter 2. Adjustments; Adjustment; Figure - Sharp XL-DV5 Service Manual

Table of Contents

Advertisement

XL-DV5/DV50
E
Market
XLDV50/5
Service Manual
XL-DV5/DV50
Audio
CHAPTER 2.
ADJUSTMENTS

[1] ADJUSTMENT

1. TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
• AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
Test Stage
Frequency
Frequency
IF
450 kHz
1,602 kHz
AM Band
530 kHz
Coverage
AM Tracking
990 kHz
990 kHz
*1. Input: IC301 1Pin
Output: IC301 23Pin
*2. Input: Input is not connected
*3. Input: Antenna
Output:IC301 23Pin
• Check FM VT
Signal generator: 1 kHz, 40 kHz dev., FM modulated
Frequency
Display
87.5 MHz
87.5 MHz
3.4V ± 1.0V
108 MHz
108 MHz
7.8V ± 1.0V
• FM Mute Level
Signal generator: 1 kHz, 40 kHz dev., FM modulated
Frequency
Display
Adjusting
98.00 MHz
98.00 MHz
VR351
(30 dBµV)
• FM Detection
Signal generator: 10.7 MHz FM sweep generator
Test
Frequency
Frequency
Stage
Display
FM IF
10.7 MHz
98.00 MHz
• FM RF
Signal generator: 1 kHz, 75 kHz dev., FM modulated
Test
Frequency
Frequency
Stage
Display
FM OSC.
87.50 MHz
FM RF
98.00 MHz
98.00 MHz
(10 ~ 20dB)
*1. Input: Antenna Output: 18 Pin of IC303
Setting/
Instrument
Display
Adjusting
Connection
Parts
T351
*1
(fL): T306
*2
1.1 ± 0.1 V
T302
*3
Output: TP-VT(IC301 28Pin)
Check
Instrument
Point
Connection
TP-VT
TP-VT
Instrument
Parts
Connection
Input: Antenna
Output: Speaker Terminal
Setting/
Instrument
Adjusting
Connection
Parts
T304
Input: Pin 1 of
IC301
Output: Pin 18
of IC303
Setting/
Instrument
Adjusting
Connection
Parts
(fL): L303
*1
3.4 ± 0.1 V
L302
*1
T351
AM IF
IC303
TP302
Figure 1 ADJUSTMENT POINTS
2. DVD/CD SECTION
Adjustment
Since this DVD/CD system incorporates the following automatic
adjustment functions, readjustment is not needed when replacing
the pickup. Therefore, different PWBs and pickups can be com-
bined freely.
Each time a disc is changed, these adjustments are performed
automatically. Therefore, playback of each disc can be performed
under optimum conditions.
2 – 1
TUNER PWB-A2
20
TP301
C393
L303
FM OSC.
VR351
FM MUTE
LEVEL
T304
FM IF
CNP301
L302
FM RF
T302
T306
AM
AM BAND
Tracking fL
COVERAGE fL

Hide quick links: