Sanyo PLC-XU56 Service Manual page 30

Multimedia projector
Hide thumbs Also See for PLC-XU56:
Table of Contents

Advertisement

Electrical Adjustments
No.
Adjustment Item
16
TEMP_UPWARNING_TIME
17
NOR_TEMP_FAN1_MIN
18
NOR_TEMP_FAN1_MAX
19
NOR_TEMP_FAN2_MIN
20
NOR_TEMP_FAN2_MAX
21
22
23
NOR_VALU_FAN1_MIN
24
NOR_VALU_FAN1_MAX
25
NOR_VALU_FAN2_MIN
26
NOR_VALU_FAN2_MAX
27
28
29
ECO_TEMP_FAN1_MIN
30
ECO_TEMP_FAN1_MAX
31
ECOTEMP_FAN2_MIN
32
ECO_TEMP_FAN2_MAX
33
34
35
ECO_VALU_FAN1_MIN
36
ECO_VALU_FAN1_MAX
37
ECO_VALU_FAN2_MIN
38
ECO_VALU_FAN2_MAX
39
40
41
HINOR_TEMP_FAN1_MIN
42
HINOR_TEMP_FAN1_MAX
43
HINOR_TEMP_FAN2_MIN
44
HINOR_TEMP_FAN2_MAX
45
46
47
HINOR_VALU_FAN1_MIN
48
HINOR_VALU_FAN1_MAX
49
HINOR_VALU_FAN2_MIN
50
HINOR_VALU_FAN2_MAX
51
52
53
HIECO_TEMP_FAN1_MIN
54
HIECO_TEMP_FAN1_MAX
55
HIECOTEMP_FAN2_MIN
56
HIECO_TEMP_FAN2_MAX
57
58
59
HIECO_VALU_FAN1_MIN
60
HIECO_VALU_FAN1_MAX
61
HIECO_VALU_FAN2_MIN
62
HIECO_VALU_FAN2_MAX
63
64
65
CLNOR_TEMP_FAN1_MIN
66
ClNOR_TEMP_FAN1_MAX
67
CLNOR_TEMP_FAN2_MIN
68
CLNOR_TEMP_FAN2_MAX
69
70
71
CLNOR_VALU_FAN1_MIN
72
CLNOR_VALU_FAN1_MAX
73
CLNOR_VALU_FAN2_MIN
74
CLNOR_VALU_FAN2_MAX
75
76
77
CLECO_TEMP_FAN1_MIN
78
CLECO_TEMP_FAN1_MAX
79
CLECOTEMP_FAN2_MIN
80
CLECO_TEMP_FAN2_MAX
81
82
83
CLECO_VALU_FAN1_MIN
84
CLECO_VALU_FAN1_MAX
85
CLECO_VALU_FAN2_MIN
86
CLECO_VALU_FAN2_MAX
87
88
89
FAN1_ADJUST_VOLT_MIN
90
FAN1_ADJUST_VOLT_MAX
91
FAN2_ADJUST_VOLT_MIN
92
FAN2_ADJUST_VOLT_MAX
93
94
Group: 112 PC Real/ AV Cinema
0
PC Real Contrast
1
PC Real Brightness
2
PC Real Red
Initial Value
Range
Input source / Description
0
0 ~ 5
+15 degrees is added to Abnormal Temperature Value during x min after power on.
44/48
Control Start Temperature for FAN1 at Normal Mode
52/54
Control End Temperature for FAN1 at Normal Mode
44/48
0~255
Control Start Temperature for FAN2 at Normal Mode
52/54
Control End Temperature for FAN2 at Normal Mode
75/75/70
Minimum Control Value for FAN1 at Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V) SU51/XU51/XU56
134/135
Maximum Control Value for FAN1 at Normal Mode
95/100
0~255
Minimum Control Value for FAN2 at Normal Mode
135/135
Maximum Control Value for FAN2 at Normal Mode
43/47
Control Start Temperature for FAN1 at Eco Mode
51/54
Control End Temperature for for FAN1 at Eco Mode
43/47
0~255
Control Start Temperature for FAN2 at Eco Mode
51/54
Control End Temperature for for FAN2 at Eco Mode
65/65/60
Minimum Control Value for FAN1 at Eco Mode
125/125/120
Maximum Control Value for FAN1 at Eco Mode
80/80/75
0~255
Minimum Control Value for FAN2 at Eco Mode
125/125/120
Maximum Control Value for FAN2 at Eco Mode
44/48
Control Start Temperature for FAN1 at Highland Normal Mode
52/54
Control End Temperature for FAN1 at Highland Normal Mode
44/48
0~255
Control Start Temperature for FAN2 at Highland Normal Mode
52/54
Control End Temperature for FAN2 at Highland Normal Mode
75/75/80
Minimum Control Value for FAN1 at Highland Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V) SU51/XU51/XU56
135/135/135
Maximum Control Value for FAN1 at Highland Normal Mode
90/95/105
0~255
Minimum Control Value for FAN2 at Highland Normal Mode
135/135/035
Maximum Control Value for FAN2 at Highland Normal Mode
43/47
Control Start Temperature for FAN1 at Highland Eco Mode
51/54
Control End Temperature for FAN1 at Highland Eco Mode
43/47
0~255
Control Start Temperature for FAN2 at Highland Eco Mode
51/54
Control End Temperature for FAN2 at Highland Eco Mode
65/65/70
Minimum Control Value for FAN1 at Highland Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V) SU51/XU51,XU56
125/125/120
Maximum Control Value for FAN1 at Highland Eco Mode
80/80/85
0~255
Minimum Control Value for FAN2 at Highland Eco Mode
125/125/120
Maximum Control Value for FAN2 at Highland Eco Mode
44/48
Control Start Temperature for FAN1 at Ceiling Normal Mode
52/54
Control End Temperature for FAN1 at Ceiling Normal Mode
44/48
0~255
Control Start Temperature for FAN2 at Ceiling Normal Mode
52/54
Control End Temperature for FAN2 at Ceiling Normal Mode
75/75/70
Minimum Control Value for FAN1 at Ceiling Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V) SU51/XU51/XU56
135/135
Maximum Control Value for FAN1 at Ceiling Normal Mode
90/95
0~255
Minimum Control Value for FAN2 at Ceiling Normal Mode
135/135
Maximum Control Value for FAN2 at Ceiling Normal Mode
43/47
Control Start Temperature for FAN1 at Ceiling Eco Mode
51/54
Control End Temperature for FAN1 at Ceiling Eco Mode
43/47
0~255
Control Start Temperature for FAN2 at Ceiling Eco Mode
51/54
Control End Temperature for FAN2 at Ceiling Eco Mode
65/65/60
Minimum Control Value for FAN1 at Ceiling Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V) SU51/XU51/XU56
125/125/120
Maximum Control Value for FAN1 at Ceiling Eco Mode
80/80/75
0~255
Minimum Control Value for FAN2 at Ceiling Eco Mode
125/125/120
Maximum Control Value for FAN2 at Ceiling Eco Mode
22/22
DAC Adjustment Value at minimum driving voltage for FAN1
230/230
DAC Adjustment Value at maximum driving voltage for FAN1
22
0~255
DAC Adjustment Value at minimum driving voltage for FAN2
230/230
DAC Adjustment Value at maximum driving voltage for FAN2
32
0 ~ 63
32
0 ~ 63
34
0 ~ 63
-30-
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51,XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
SU51/XU51/XU56
✻ Fan Control Adjustment
SU51/XU51/XU56
✻ Fan Control Adjustment
SU51/XU51/XU56
✻ Fan Control Adjustment
SU51/XU51/XU56
✻ Fan Control Adjustment
SU51/XU51/XU56