Download Print this page

Important Safety Instructions; Save These Instructions - Vector VEC049D User's Manual & Warranty Information

Inverter remote switch
Hide thumbs Also See for VEC049D:

Advertisement

VEC003_Manual_011606
1/26/06

IMPORTANT SAFETY INSTRUCTIONS

WARNING
TO REDUCE THE RISK OF INJURY, user must read and understand
this User's Manual and the supplied documentation for the Inverter
and all devices to be used with the unit.
CAUTIONS
• This unit is NOT waterproof. DO NOT submerge it in liquids of any kind or use
it in the rain, snow or other wet conditions.
• Make sure the cord is placed so it is not tripped over or damaged by pinching,
abrading or cutting. Do not place it near moving objects, doors or sharp
objects, or expose it to extreme heat. Discontinue use if the cord is damaged.
• This is not a toy — keep away from children.
• Do not operate unit if there is any evidence of damage. To replace worn or
defective parts, contact Customer Service Department, toll-free, at (866) 584-5504.

SAVE THESE INSTRUCTIONS

INTRODUCTION
Thank you for purchasing the VEC003 Inverter Remote Switch . The
Remote Power Switch allows Vector power inverters to be controlled
remotely.
FEATURES
• Power/Fault LED Indicators
• 20' cord with telephone-type connector
• Mountable Switch Plate
• Electronic pushbutton control
OPERATING THE UNIT
1. Position the Switch Plate, following the recommendations in the
"Important Safety Instructions." The Switch Plate may be mounted
for convenience.
3:32 PM
Page 3
The pushbutton control and Power/Fault LED Indicators function exactly
as they do on the inverter. Refer to the inverter manual for further
operating information, load recommendations and specifications.
Note: The inverter's ON/OFF Switch must be in the OFF position
ALWAYS turn the inverter OFF using the Remote Switch Plate before
disconnecting this unit from the inverter. Failure to do so will disable use
of the inverter's ON/OFF function.
2. Plug the extension cord into the inverter's Remote Control
Connection Port.
3. Operate the inverter as usual.
before connecting the Remote Switch Plate and remain in the
OFF position. All ON/OFF function should be controlled by
the Remote Switch Plate.
CAUTION
TWO YEARS LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities
of Vector Manufacturing, regarding this product. There is no other warranty, other than those described herein.
Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration
to the duration of this warranty.
This Vector Manufacturing product is warranted, to the original purchaser only, to be free of defects in materials
and workmanship for two years from the date of purchase without additional charge. The warranty does not
extend to subsequent purchasers or users. Manufacturer will not be responsible for any amount of damage in
excess of the retail purchase price of the product under any circumstances. Incidental and consequential damages
are specifically excluded from coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to damage to units from misuse or
incorrect installation/connection. Misuse includes wiring or connecting to improper polarity power sources.
RETURN/REPAIR POLICY: Defective products may be returned to manufacturer. Any defective product that is
returned to manufacturer within 30 days of the date of purchase will be replaced free of charge. If such a product
is returned more than 30 days but less than two years from the purchase date, manufacturer will repair the unit
or, at its option, replace it, free of charge.
continues

Advertisement

loading

This manual is also suitable for:

Vec051dVec050dVec053dVec054dVec056dVec003