Check power source.
Check control switch
setting.
Only compressor fails to
start.
Drop of power voltage.
Defect of compressor
capacitor.
Check capacitor.
Replacement.
Irregular motor resistance ( )
Irregular motor insulation ( )
Replacement of compressor
(Motor damaged)
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Fails to Start
Improper thermostat setting
Loose terminal connection.
Improper wiring
- 44 -
Check circuit breaker
and fuse.
Gas leakage of feeler bulb
of thermostat
Check control switch.
Only fan fails to start.
Improper wiring.
Defect of fan motor
capacitor.
Irregular motor resistance
(
).
Irregular motor insulation
(
).
Replacement of fan motor
Regular but fails to start
Replacement of compressor
(locking of rotor, metal)
LGE Internal Use Only