Other
7.Other
Icemaker and defrost details
1.You can manually start a defrost cycle according to Pressing FRZ< , FRZ> temp
adjust keys and RESET(or TEST) for 3 seconds.There will be "T1,T1" on display
panel.
2.Generally speaking,there will be a deforst cycle after 7 hours working of
compressor.If there is less door openings or the temperature is proper,the defrost
cycle will increase,maybe 90 hours.
3.And the humidity sensor does not matter with the defrost cycle.
4.Center mullion heater will be function under certain time proportion if the
humidity is heavy or more door openings.
5.The Center mullion heater will stop working under proper humidity or less door
openings.
6.And it's 25W,529 .There are the technical datas in connect diagram in service
manual.
7.The icemaker will stop when drawer is opened even in harvest time.
8.You can manually start the icemaker according to pressing FRZ< and REF>
temp adjust keys for 3 seconds,the icemaker will cycle one time.
9.You can adjust the water lever according to controlling the time of water
infusing.Press the 2 time adjust keys for 3 seconds,then the function of water
infusing is available.
10.When you adjust the water level,you will see "CC".It means milliliter.

Advertisement