Seagate ST39102FC Product Manual page 27

Fibre channel disc drives
Table of Contents

Advertisement

Cheetah 9LP FC Product Manual, Rev. C
The disc drive defaults to the FC-AL Monitoring state, Pass-through state, when it is powered-on by switching
the power or hot plugged. The control line to an optional port bypass circuit (external to the drive), defaults to
the Enable Bypass state. If the bypass circuit is present, the next device in the loop will continue to receive the
output of the previous device to the newly inserted device. If the bypass circuit is not present, loop operation is
temporarily disrupted until the next device starts receiving the output from the newly inserted device and
regains synchronization to the new input.
The Pass-through state is disabled while the drive performs self test of the FC interface. The control line for an
external port bypass circuit remains in the Enable Bypass state while self test is running. If the bypass circuit is
present, loop operation may continue. If the bypass circuit is not present, loop operation will be halted while the
self test of the FC interface runs.
When the self test completes successfully, the control line to the bypass circuit is disabled and the drive enters
the FC-AL Initializing state. The receiver on the next device in the loop must synchronize to output of the newly
inserted drive.
If the self-test fails, the control line to the bypass circuit remains in the Enable Bypass state.
Note.
It is the responsibility of the systems integrator to assure that no temperature, energy, voltage hazard,
or ESD potential hazard is presented during the hot connect/disconnect operation. Discharge the static
electricity from the drive carrier prior to inserting it into the system.
Caution.
The drive motor must come to a complete stop prior to changing the plane of operation. This time is
required to insure data integrity.