Download Print this page

Sanyo KMS1872 Specifications

Wall mounted indoor unit - multi air conditioner
Hide thumbs Also See for KMS1872:

Advertisement

Multi/Split System Submittal Data
KMS1872
Wall Mounted Indoor Unit - Multi Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/P/Hz
Circuit Ampacity
Fuse Size, Max.
(A)
Running Amps
Power Input
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
(RPM, High)
No. Motors
CFM
Operation Sound
(HI/Med/Lo/QT* dB-A)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
(in.)
Drain Connection Size
Refrigerant
(in. O.D. Discharge)
Line Size
(in. O.D. Discharge)
Line Size
Dimensions
(in.)
Indoor Unit
(Uncrated)
(Crated)
Weight
Net Shipping
Shipping Volume
General Data (at 230V)
230/1/60
(A)
(A)
(W)
Cross Flow
D3-11/16 L33-9/32-1
3 & Auto
8 - 1200
(W)
(HI)
41/38/34/28
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riff ed
2 - 19.5
23/32"
R410A
1/4"(Flare)
1/2"(Flare)
H x W x D
11-23/32 x 41-15/16 x 8-19/32
11-3/8 x 44-7/8 x 14-29/32
Indoor
(lbs.)
(lbs.)
(cu.ft.)
Approval:
Date:
Construction:
Unit #:
Drawing #:
15
20
.15
35
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
30 - 1
Moisture Removal (HI)
500
Feature
Controls
Remote Controller
Temperature Control
Timer
3.07
Night Setback
Air Louver
9/32"
Power Failure Automatic Restart
Heating/Cooling Automatic Changeover
Self-Diagnosis
Quiet Operation
Air Filter
Ion Generator
Air Clean Apatite Filer
Option
Refrigerant Line Set
26.5
Fresh Air Intake
33.1
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Indoor
4.23
Non-Removeable Remo-con Bracket
(BTU/H)
(Pint/H)
Microprocessor
LCD Wireless Type, Temp. Sensor Built In
24 Hr. Program, 1 Hr. Off
(Horizontal)
(Vertical)
Washable, Anti-Mold
17,500
4.89
IC Thermostat
Built-In
Manual
Automatic
Built-In
-
Built-In
Built-In
Equipped
Standard
Available
N/A
N/A
N/A
Available
Available

Advertisement

loading

Summary of Contents for Sanyo KMS1872

  • Page 1 Print Form Multi/Split System Submittal Data KMS1872 Wall Mounted Indoor Unit - Multi Air Conditioner Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/P/Hz 230/1/60 Circuit Ampacity Fuse Size, Max.
  • Page 2 Maximum 67F DB/57F WB 67F DB Minimum Note (CLM Model): 1 32F DB: When combinded with KMS1872 or KMS2472 23F DB: When combinded with KMS0772, KMS0972, or KMS1272 Sanyo Commercial Solutions A Division of SANYO North America 1300 Michael Drive Wood Dale, IL 60191 USA www.sanyohvac.com...